Abstract

This paper presents the NSX front-end ASIC, being developed to read charge signals from the HEMA and WFM X-ray detectors for the STROBE-X mission. The ASIC reads out signals from up to 64 anodes of linear Silicon Drift Detectors (SDDs). When unloaded, the ASIC channel has a charge resolution, expressed in Equivalent Noise Charge (ENC) of about 2.8 e-. Once connected to the SDD anode we anticipate, for the 80 keV energy range, a ENC of about 10.7 e- at a leakage current of 2 pA, which corresponds to a FWHM of about 145 eV at 6 keV once the Fano-limited statistics from charge generation in Si is included. The acquisition is event-triggered and, for events exceeding the threshold, the ASIC measures the peak amplitude and stores it in an analog memory for subsequent readout. The ASIC can also force the measurement of the sub-threshold channels neighboring the triggered channel, including the ones that belong to neighbor chips by using bi-directional differential inter-chip communication. Alternatively, the ASIC can measure the amplitudes of all channels at the time of the first detected peak. Additional features include a high-resolution option, channel power down and skip function, a low-noise pulse generator, a temperature sensor, and the monitoring of the channel analog output and trimmed threshold. The power consumption of the individual channel is ~590 $\mu$W and, when including all shared circuits, it averages to ~670 $\mu$W / channel.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gianluigi De Geronimo, Paul S. Ray, Eric A. Wulf, Colleen A. Wilson-Hodge, Eric Burns, Yuri Evangelista, Anthony Hutcheson, Thomas J. Maccarone, Gianluigi Zampa. 2024-10-10. Front-End ASIC for the STROBE-X HEMA and WFM Detectors: Concept and Design. https://arxiv.org/abs/2410.08344

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det