arXiv Science⌕ Search

arXiv · 2409.18701

3DPX: Single Panoramic X-ray Analysis Guided by 3D Oral Structure Reconstruction

Abstract

Panoramic X-ray (PX) is a prevalent modality in dentistry practice owing to its wide availability and low cost. However, as a 2D projection of a 3D structure, PX suffers from anatomical information loss and PX diagnosis is limited compared to that with 3D imaging modalities. 2D-to-3D reconstruction methods have been explored for the ability to synthesize the absent 3D anatomical information from 2D PX for use in PX image analysis. However, there are challenges in leveraging such 3D synthesized reconstructions. First, inferring 3D depth from 2D images remains a challenging task with limited accuracy. The second challenge is the joint analysis of 2D PX with its 3D synthesized counterpart, with the aim to maximize the 2D-3D synergy while minimizing the errors arising from the synthesized image. In this study, we propose a new method termed 3DPX - PX image analysis guided by 2D-to-3D reconstruction, to overcome these challenges. 3DPX consists of (i) a novel progressive reconstruction network to improve 2D-to-3D reconstruction and, (ii) a contrastive-guided bidirectional multimodality alignment module for 3D-guided 2D PX classification and segmentation tasks. The reconstruction network progressively reconstructs 3D images with knowledge imposed on the intermediate reconstructions at multiple pyramid levels and incorporates Multilayer Perceptrons to improve semantic understanding. The downstream networks leverage the reconstructed images as 3D anatomical guidance to the PX analysis through feature alignment, which increases the 2D-3D synergy with bidirectional feature projection and decease the impact of potential errors with contrastive guidance. Extensive experiments on two oral datasets involving 464 studies demonstrate that 3DPX outperforms the state-of-the-art methods in various tasks including 2D-to-3D reconstruction, PX classification and lesion segmentation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Xiaoshuang Li, Zimo Huang, Mingyuan Meng, Eduardo Delamare, Dagan Feng, Lei Bi, Bin Sheng, Lingyong Jiang, Bo Li, Jinman Kim. 2024-09-27. 3DPX: Single Panoramic X-ray Analysis Guided by 3D Oral Structure Reconstruction. https://arxiv.org/abs/2409.18701

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

SCI-Mamba: Unsupervised Learning based Low-Light Image Enhancement for Non-Cooperative Spacecraft

Low-light visual perception acts as the core visual foundation for on-orbit servicing missions targeting non-cooperative spacecraft, supporting autonomous rendezvous, pose estimation, component detection and robotic capture operations. Spaceborne imagery suffers from severe low-light degradation, while the extreme scarcity of paired normal/low-light space samples severely limits the generalization capacity of supervised enhancement algorithms. To address this practical bottleneck, this paper proposes SCI-Mamba, an unsupervised enhancement network for low-light orbital spacecraft observations. The proposed framework unites self-calibrated unsupervised learning, linear-complexity VMamba architecture and Retinex physical priors, delivering a lightweight enhancement pipeline adaptable to resource-limited spaceborne hardware. We construct Space Dark-1.0, a dedicated low-light spacecraft dataset integrating real orbital footage, darkroom hardware-in-the-loop measurements and physically constrained synthetic data covering diverse illumination, motion and attitude conditions. Comprehensive comparisons with CNN-, Transformer- and prevailing Mamba-based approaches verify the advantages of SCI-Mamba in visual authenticity, color fidelity and inference speed. The proposed framework provides a practical low-light enhancement solution for close-proximity non-cooperative space operations. The code is available at https://github.com/bitswh/SCI-Mamba

eess.IV↗

UEPS: Robust and Efficient MRI Reconstruction

Deep unrolled models (DUM) have become the state-of-the-art for accelerated MRI reconstruction, yet their robustness under domain shift remains a critical barrier to clinical adoption. In this work, we identify coil sensitivity map (CSM) estimation as the primary bottleneck limiting generalization. To address this, we propose UEPS, a novel DUM architecture featuring three key designs: (i) an Unrolled Expanded (UE) design that eliminates CSM dependency by reconstructing each coil independently; (ii) progressive resolution, which leverages k-space-to-image mapping for efficient coarse-to-fine refinement; and (iii) sparse attention tailored to MRI's 1D undersampling nature. These physics-grounded designs enable gains in robustness and computational efficiency. We construct a large-scale zero-shot transfer benchmark comprising 10 out-of-distribution (OOD) test sets spanning diverse clinical shifts, anatomy, view, contrast, vendor, field strength, and coil configurations. Extensive experiments demonstrate that UEPS consistently and substantially outperforms existing DUM, end-to-end, diffusion, and untrained methods across all OOD tests, achieving state-of-the-art robustness with low-latency inference suitable for real-time deployment.

eess.IV↗

Forecasting Brain Tracer Distribution from Pre-Contrast MRI: A Comparison of Direct Regression and Flow Matching

Intrathecal contrast-enhanced MRI shows how a tracer injected into the cerebrospinal fluid spreads through the brain, but requires repeated scans over 24--48\,h. We therefore ask how much of the later tracer distribution can be predicted from the pre-contrast scan and elapsed time alone. Using 104 training patients (878 MRI volumes), we compared a direct image-to-image regression model with a more complex generative model based on conditional flow matching, and tested both on 23 held-out patients and on 51 patients from a separate cohort with idiopathic normal pressure hydrocephalus (INPH). The direct model reduced the error of simply copying the pre-contrast scan by about 60\% in held-out patients and 25\% in the INPH cohort, and its predicted change maps agreed with the observed tracer enhancement rather than only reproducing anatomy. The generative model was less accurate in both cohorts. A substantial part of the later tracer distribution is therefore predictable from the patient's brain anatomy as seen on pre-contrast MRI, and the added model complexity gave no benefit at this data scale. With prospective validation, such forecasts could be studied for patient stratification and treatment planning in intrathecal therapies.

eess.IV↗