arXiv ScienceSearch

arXiv · 2409.02030

Design of a large-scale superconducting dipole magnet for the CEE spectrometer

Abstract

The CSR External-target Experiment (CEE) is a large-scale spectrometer under construction at the Heavy Ion Research Facility in Lanzhou (HIRFL) for studying the phase structure of nuclear matter at high baryon density and the equation of states of nuclear matter at supra-saturation densities. One of the key components is a large acceptance dipole magnet with a central field of 0.5 T and the homogeneity of 5% within a 1 m long, 1.2 m wide, and 0.9 m high aperture. Detectors will be installed within this aperture. An innovative design for the superconducting detector magnet is proposed that goes beyond the conventional approach. The magnet is designed as a coil-dominant type, with conductors discretized on a racetrack-shaped cross-section to generate the necessary fields. A warm iron yoke is used to enhance the central field and minimize the stray field. The magnet has overall dimensions of 3.4 meters in length, 2.7 meters in height, and 4.3 meters in width. The coils will be wound using a 19-strand rope cable comprised of 12 NbTi superconducting wires and 7 copper wires. The ratio of copper to superconductor of the cable is 6.9. The keel supports serve as the primary structural support for the coils to withstand the electromagnetic force. The coils will be indirectly cooled by liquid helium within three external helium vessels. To ensure reliable protection of the magnet during a quench, an active protection method combined with quench-back effect is employed. In this paper, we mainly present the detailed design of the magnetic field, structure, quench protection and cryostat for the spectrometer magnet.

Explore related subjects

Keep this discovery

BibTeXRIS

Yuquan Chen, Wei You, Jiaqi Lu, Yujin Tong, Luncai Zhou, Beimin Wu, Enming Mei, Wentian Feng, Xianjin Ou, Wei Wu, Qinggao Yao, Peng Yang, Yuhong Yu, Zhiyu Sun. 2024-09-03. Design of a large-scale superconducting dipole magnet for the CEE spectrometer. https://arxiv.org/abs/2409.02030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det