An automated and time efficient framework for simulation of coronary blood flow under steady and pulsatile conditions

Abstract

Fractional flow reserve (FFR) is the gold standard for diagnosing coronary artery disease (CAD). FFRCT uses computational fluid dynamics (CFD) to evaluate FFR non-invasively by simulating coronary flow in geometries reconstructed from computed tomography (CT). However, it faces challenges related to the cost of computing and uncertainties in defining patient-specific boundary conditions (BCs). We investigated using time-averaged steady BCs instead of pulsatile ones to reduce computational time and deployed a self-adjusting method for tuning BCs to patient clinical data. 133 coronary arteries were reconstructed from CT images of CAD patients. For each vessel, invasive FFR was measured. Steady BCs for CFD were defined in two steps: i) rest BCs were extrapolated from clinical and image-derived data; ii) hyperemic BCs were computed from resting conditions. Flow rate was iteratively adjusted during the simulation until patient aortic pressure was matched. Pulsatile BCs were defined using the convergence values of steady BCs. Lesion-specific hemodynamic indexes were computed and compared between groups of patients indicated for surgery and those not. The whole pipeline was implemented as a straightforward, fully automated process. Steady and pulsatile FFRCT showed a strong correlation (r=0.988) and correlated with invasive FFR (r=0.797). The per-point difference between the pressure and FFRCT field predicted by the two methods was below 0.01 and 0.02, respectively. Both approaches exhibited good diagnostic performance: accuracy was 0.860 and 0.864, with AUCs of 0.923 and 0.912, for steady and pulsatile cases, respectively. Computational time for steady BCs CFD was approximately 30-fold lower than for the pulsatile case. This work demonstrates the feasibility of using steady BCs CFD for computing FFRCT in coronary arteries and its performance in a fully automated pipeline.

Explore related subjects

Keep this discovery

BibTeXRIS

Guido Nannini, Simone Saitta, Luca Mariani, Riccardo Maragna, Andrea Baggiano, Saima Mushtaq, Gianluca Pontone, Alberto Redaelli. 2024-08-29. An automated and time efficient framework for simulation of coronary blood flow under steady and pulsatile conditions. https://arxiv.org/abs/2408.16496

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph