arXiv ScienceSearch

arXiv · 2407.10377

Enhanced Masked Image Modeling to Avoid Model Collapse on Multi-modal MRI Datasets

Abstract

Multi-modal magnetic resonance imaging (MRI) provides information of lesions for computer-aided diagnosis from different views. Deep learning algorithms are suitable for identifying specific anatomical structures, segmenting lesions, and classifying diseases. Manual labels are limited due to the high expense, which hinders further improvement of accuracy. Self-supervised learning, particularly masked image modeling (MIM), has shown promise in utilizing unlabeled data. However, we spot model collapse when applying MIM to multi-modal MRI datasets. The performance of downstream tasks does not see any improvement following the collapsed model. To solve model collapse, we analyze and address it in two types: complete collapse and dimensional collapse. We find complete collapse occurs because the collapsed loss value in multi-modal MRI datasets falls below the normally converged loss value. Based on this, the hybrid mask pattern (HMP) masking strategy is introduced to elevate the collapsed loss above the normally converged loss value and avoid complete collapse. Additionally, we reveal that dimensional collapse stems from insufficient feature uniformity in MIM. We mitigate dimensional collapse by introducing the pyramid barlow twins (PBT) module as an explicit regularization method. Overall, we construct the enhanced MIM (E-MIM) with HMP and PBT module to avoid model collapse multi-modal MRI. Experiments are conducted on three multi-modal MRI datasets to validate the effectiveness of our approach in preventing both types of model collapse. By preventing model collapse, the training of the model becomes more stable, resulting in a decent improvement in performance for segmentation and classification tasks. The code is available at https://github.com/LinxuanHan/E-MIM.

Explore related subjects

Keep this discovery

BibTeXRIS

Linxuan Han, Sa Xiao, Zimeng Li, Haidong Li, Xiuchao Zhao, Yeqing Han, Fumin Guo, Xin Zhou. 2024-07-15. Enhanced Masked Image Modeling to Avoid Model Collapse on Multi-modal MRI Datasets. https://arxiv.org/abs/2407.10377

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV