arXiv ScienceSearch

arXiv · 2406.11937

Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter

Abstract

A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadronic section. The shower reconstruction method is based on graph neural networks and it makes use of a dynamic reduction network architecture. It is shown that the algorithm is able to capture and mitigate the main effects that normally hinder the reconstruction of hadronic showers using classical reconstruction methods, by compensating for fluctuations in the multiplicity, energy, and spatial distributions of the shower's constituents. The performance of the algorithm is evaluated using test beam data collected in 2018 prototype of the CMS HGCAL accompanied by a section of the CALICE AHCAL prototype. The capability of the method to mitigate the impact of energy leakage from the calorimeter is also demonstrated.

Explore related subjects

Keep this discovery

BibTeXRIS

M. Aamir, G. Adamov, T. Adams, C. Adloff, S. Afanasiev, C. Agrawal, A. Ahmad, H. A. Ahmed, S. Akbar, N. Akchurin, B. Akgul, B. Akgun, R. O. Akpinar, E. Aktas, A. Al Kadhim, V. Alexakhin, J. Alimena, J. Alison, A. Alpana, W. Alshehri, P. Alvarez Dominguez, M. Alyari, C. Amendola, R. B. Amir, S. B. Andersen, Y. Andreev, P. D. Antoszczuk, U. Aras, L. Ardila, P. Aspell, M. Avila, I. Awad, O. Aydilek, Z. Azimi, A. Aznar Pretel, O. A. Bach, R. Bainbridge, A. Bakshi, B. Bam, S. Banerjee, D. Barney, O. Bayraktar, F. Beaudette, F. Beaujean, E. Becheva, P. K. Behera, A. Belloni, T. Bergauer, M. Besancon, O. Bessidskaia Bylund, L. Bhatt, S. Bhattacharya, D. Bhowmil, F. Blekman, P. Blinov, P. Bloch, A. Bodek, a. Boger, A. Bonnemaison, F. Bouyjou, L. Brennan, E. Brondolin, A. Brusamolino, I. Bubanja, A. Buchot Perraguin, P. Bunin, A. Burazin Misura, A. Butler-nalin, A. Cakir, S. Callier, S. Campbell, Y. B. Candemir, K. Canderan, K. Cankocak, A. Cappati, S. Caregari, S. Carron, C. Carty, A. Cauchois, L. Ceard, S. Cerci, P. J. Chang, R. M. Chatterjee, S. Chatterjee, P. Chattopadhyay, T. Chatzistavrou, M. S. Chaudhary, J. A. Chen, J. Chen, Y. Chen, K. Cheng, H. Cheung, J. Chhikara, A. Chiron, M. Chiusi, D. Chokheli, R. Chudasama, E. Clement, S. Coco Mendez, D. Coko. 2024-06-17. Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter. https://doi.org/10.1088/1748-0221/19/11/p11025

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det