arXiv · 2404.09733
Semiconductor Devices Condition Monitoring Using Harmonics in Inverter Control Variables
Abstract
The health status of power semiconductor devices in power converters is important but difficult to monitor. This paper analyzes the relationship between harmonics in inverter control variables and a health precursor (the on-state voltage Von of power semiconductor devices). Based on the analysis, harmonics can estimate Von without adding extra sensing circuits. The method is validated through simulations.
Explore related subjects
Keep this discovery
Shuyu Ou, Ariya Sangwongwanich, Subham Sahoo, Frede Blaabjerg. 2024-04-15. Semiconductor Devices Condition Monitoring Using Harmonics in Inverter Control Variables. https://doi.org/10.23919/epe23ecceeurope58414.2023.10264538