arXiv · 2401.11875
Design and characterisation of an antiproton deceleration beamline for the PUMA experiment
Abstract
We report on the design and characterization of an antiproton deceleration beamline, based on a pulsed drift tube, for the PUMA experiment at the Antimatter Factory at CERN. The design has been tailored to high-voltage (100 kV) and ultra-high vacuum (below $10^{-10}$ mbar) conditions. A first operation achieved decelerating antiprotons from an initial energy of 100 keV down to ($3898\pm 3$) eV, marking the initial stage in trapping antiprotons for the PUMA experiment. Employing a high-voltage ramping scheme, the pressure remains below $2\cdot 10^{-10}$ mbar upstream of the pulsed drift tube for 75% of the cycle time. The beamline reached a transmission of ($55 \pm 3$)% for antiprotons decelerated to 4 keV. The beam is focused on a position sensitive detector to a spot with horizontal and vertical standard deviations of ${\sigma}_\mathrm{horiz}$ = ($3.0 \pm 0.1$) mm and ${\sigma}_\mathrm{vert}$ = ($3.8 \pm 0.2$) mm, respectively. This spot size is within the acceptance of the PUMA Penning trap.
Explore related subjects
Keep this discovery
J. Fischer, A. Schmidt, N. Azaryan, F. Butin, J. Ferreira Somoza, A. Husson, C. Klink, A. Obertelli, M. Schlaich, A. Sinturel, N. Thaus, F. Wienholtz. 2024-01-22. Design and characterisation of an antiproton deceleration beamline for the PUMA experiment. https://doi.org/10.1016/j.nimb.2024.165318
Cite the original work for its findings. Save a collection to share your selection of sources.