arXiv ScienceSearch

arXiv · 2311.02927

Auto-ICell: An Accessible and Cost-Effective Integrative Droplet Microfluidic System for Real-Time Single-Cell Morphological and Apoptotic Analysis

Abstract

The Auto-ICell system, a novel, and cost-effective integrated droplet microfluidic system, is introduced for real-time analysis of single-cell morphology and apoptosis. This system integrates a 3D-printed microfluidic chip with image analysis algorithms, enabling the generation of uniform droplet reactors and immediate image analysis. The system employs a color-based image analysis algorithm in the bright field for droplet content analysis. Meanwhile, in the fluorescence field, cell apoptosis is quantitatively measured through a combination of deep-learning-enabled multiple fluorescent channel analysis and a live/dead cell stain kit. Breast cancer cells are encapsulated within uniform droplets, with diameters ranging from 70 μm to 240 μm, generated at a high throughput of 1,500 droplets per minute. Real-time image analysis results are displayed within 2 seconds on a custom graphical user interface (GUI). The system provides an automatic calculation of the distribution and ratio of encapsulated dyes in the bright field, and in the fluorescent field, cell blebbing and cell circularity are observed and quantified respectively. The Auto-ICell system is non-invasive and provides online detection, offering a robust, time-efficient, user-friendly, and cost-effective solution for single-cell analysis. It significantly enhances the detection throughput of droplet single-cell analysis by reducing setup costs and improving operational performance. This study highlights the potential of the Auto-ICell system in advancing biological research and personalized disease treatment, with promising applications in cell culture, biochemical microreactors, drug carriers, cell-based assays, synthetic biology, and point-of-care diagnostics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yuanyuan Wei, Meiai Lin, Shanhang Luo, Syed Muhammad Tariq Abbasi, Liwei Tan, Guangyao Cheng, Bijie Bai, Yi-Ping Ho, Scott Wu Yuan, Ho-Pui Ho. 2023-11-06. Auto-ICell: An Accessible and Cost-Effective Integrative Droplet Microfluidic System for Real-Time Single-Cell Morphological and Apoptotic Analysis. https://arxiv.org/abs/2311.02927

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

VideoPulse: Neonatal heart rate and peripheral capillary oxygen saturation (SpO2) estimation from contact free video

Remote photoplethysmography (rPPG) enables contact free monitoring of vital signs and is especially valuable for neonates, since conventional methods often require sustained skin contact with adhesive probes that can irritate fragile skin and increase infection control burden. We present VideoPulse, a neonatal dataset and an end to end pipeline that estimates neonatal heart rate and peripheral capillary oxygen saturation (SpO2) from facial video. VideoPulse contains 157 recordings totaling 2.6 hours from 52 neonates with diverse face orientations. Our pipeline performs face alignment and artifact aware supervision using denoised pulse oximeter signals, then applies 3D CNN backbones for heart rate and SpO2 regression with label distribution smoothing and weighted regression for SpO2. Predictions are produced in 2 second windows. On the NBHR neonatal dataset, we obtain heart rate MAE 2.97 bpm using 2 second windows (2.80 bpm at 6 second windows) and SpO2 MAE 1.69 percent. Under cross dataset evaluation, the NBHR trained heart rate model attains 5.34 bpm MAE on VideoPulse, and fine tuning an NBHR pretrained SpO2 model on VideoPulse yields MAE 1.68 percent. These results indicate that short unaligned neonatal video segments can support accurate heart rate and SpO2 estimation, enabling low cost non invasive monitoring in neonatal intensive care.

eess.IV

Synthetic Fingerprints for Children Under Four: Generation and Biometric Evaluation

Fingerprint recognition in children under four is of interest for longitudinal identity applications, but research in this age range is constrained by the limited availability and sensitivity of real fingerprint data. Synthetic data may provide a useful complementary resource if generated samples are carefully evaluated for biometric quality, similarity to the real training data, and identity diversity. This paper presents an evaluation and selection protocol for synthetic fingerprints generated from a small pediatric dataset. The protocol was applied to 32,000 candidates produced by an age-conditioned generator fine-tuned with 205 fingerprints from nine children. Candidates were evaluated using NFIQ 2, NBIS minutiae extrac-tion and matching, fingerprint-pattern classification, similarity to the complete real reference set, and pairwise similarity among retained synthetic samples. After candidate filtering and a final symmetric pairwise verification, 1,985 synthetic fingerprints remained. The youngest age group continued to produce retained samples within the sampling budget, whereas the oldest original age group produced 24 retained prints. A data-derived two-group age representation improved pattern-distribution agreement for the younger group. Repeated renderings of fixed synthetic iden-tities produced minutiae-based mated scores comparable to the real mated scores, although a DINOv2 texture representation showed substantially greater within-generator similarity. The results indicate that synthetic pediatric fingerprints can support controlled research use, but their evaluation should include both real-to-synthetic similarity and synthetic-to-synthetic diversity, and conclusions should remain specific to the matchers and measurements used.

eess.IV

Adaptive Color Grading

Independent control of tonescale regions (e.g., shadows, highlights) is essential for painters, photographers and cinematographers to bring 2D images to life. In image manipulation software this is most directly addressed by color grading modules, which use intensity thresholds to segment distinct illumination regions for local manipulation. In this work we develop an open source color grading tool and use it to annotate a large dataset of video frames with tonescale region thresholds. Using these thresholds we conduct modeling experiments with strategies based on both practitioners' conventional wisdom and machine learning. Results show that K-nearest neighbors is an effective prediction strategy, outperforming state-of-the-art end-to-end methods for image enhancement. This outcome demonstrates the benefit of focusing on a compact set of core parameters when modeling creative stylization processes. Our adaptive color grading interface and data are available at https://github.com/SamsungLabs/adaptive-color-grading.

eess.IV