arXiv ScienceSearch

arXiv · 2306.04106

Prediction of nanobubble-assisted focused ultrasound-induced blood-brain barrier opening with machine learning

Abstract

Novel approaches for predicting the outcomes of blood-brain barrier (BBB) opening with focused ultrasound (FUS) and microbubbles are highly desired. This study aims to explore machine learning-based methods for reliably predicting the FUS-induced BBB opening efficacy and safety. Methods: Sixteen female rats were used in this study. An acoustic feedback-controlled FUS system (f0: 0.5MHz) was used for the BBB opening with the infusion of custom-made nanobubbles/Definity. Evans Blue was injected for the BBB opening efficacy verification and the brain tissue was harvested for the safety assessment. Acoustic emissions were recorded, preprocessed and fed into three machine learning models for BBB opening outcomes prediction. Conventional stable and inertial cavitation dose were also calculated. Results: Among the tested machine learning models, a modified Support Vector Data Description (mSVDD) model achieved the best performance in the BBB opening efficacy and safety prediction with an accuracy of 85.0+/-16.6% and 62.5+/-12.8%, respectively. Conventional stable and inertial cavitation dose-based prediction has a prediction accuracy of 80.0% in efficacy and 34.3% in safety, respectively. The mSVDD model trained with the overall bubble response (0-2 MHz) performed better than that trained with the ultra-harmonic bubble response (0.7-0.8 MHz) in both efficacy prediction (85.0+/-16.6% vs 76.0+/-8.0%, p=0.04) and safety prediction (62.5+/-12.8% vs 55.0+/-10.7%, p>0.05). It is also found that the mSVDD model trained with nanobubble data cannot be directly applied to Definity. Conclusion: Our investigations demonstrated that it is feasible to achieve a reliable prediction of FUS-induced BBB opening outcomes with machine learning and acoustic signals from stimulated nanobubbles. This study provided a new approach for the prediction of FUS-BBB opening outcomes with a clinical translation potential.

Explore related subjects

Keep this discovery

BibTeXRIS

Wenjing Li, Chenchen Bing, Haixin Dai, Rajiv Chopra, Qian Wang, Bingbing Cheng. 2023-06-07. Prediction of nanobubble-assisted focused ultrasound-induced blood-brain barrier opening with machine learning. https://arxiv.org/abs/2306.04106

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph