arXiv ScienceSearch

arXiv · 2303.00896

Absolute frequency measurements with a robust, transportable ^{40}Ca^{+} optical clock

Abstract

We constructed a transportable 40Ca+ optical clock (with an estimated minimum systematic shift uncertainty of 1.3*10^(-17) and a stability of 5*10^(-15)/sqrt{tau} ) that can operate outside the laboratory. We transported it from the Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan to the National Institute of Metrology, Beijing. The absolute frequency of the 729 nm clock transition was measured for up to 35 days by tracing its frequency to the second of International System of Units. Some improvements were implemented in the measurement process, such as the increased effective up-time of 91.3 % of the 40Ca+ optical clock over a 35-day-period, the reduced statistical uncertainty of the comparison between the optical clock and hydrogen maser, and the use of longer measurement times to reduce the uncertainty of the frequency traceability link. The absolute frequency measurement of the 40Ca+ optical clock yielded a value of 411042129776400.26 (13) Hz with an uncertainty of 3.2*10^(-16), which is reduced by a factor of 1.7 compared with our previous results. As a result of the increase in the operating rate of the optical clock, the accuracy of 35 days of absolute frequency measurement can be comparable to the best results of different institutions in the world based on different optical frequency measurements.

Explore related subjects

Keep this discovery

BibTeXRIS

Huaqing Zhang, Yao Huang, Baolin Zhang, Yanmei Hao, Mengyan Zeng, Qunfeng Chen, Yuzhuo Wang, Shiying Cao, Yige Lin, Zhanjun Fang, Hua Guan, Kelin Gao. 2023-03-02. Absolute frequency measurements with a robust, transportable ^{40}Ca^{+} optical clock. https://doi.org/10.1088/1681-7575/acd05d

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Delay-engineered dynamical phases in a programmable non-Markovian spin oscillator

Non-Markovian dynamics offer a new route towards engineering non-equilibrium matter, where memory and feedback act as programmable resources for controlling order in time. Here we report the realization of a non-Markovian spin oscillator in a hot vapour $^{129}$Xe-Cs co-magnetometer with programmable feedback delay and gain. By tuning these parameters, we observe a hierarchy of dynamical phases, including time-crystalline response, nonlinear bifurcations, and frequency-comb formation. The measured spectra and phase boundaries are captured by linear stability analysis of delayed Bloch equations, revealing these phenomena as different manifestations of the same memory-induced instability structure. These results establish time-delayed feedback as a powerful strategy for controlling non-equilibrium phases, enabling quantum sensing, frequency referencing, and synchronization within a single spin-based platform.

physics.atom-ph

Non-stick vacuum wall collisions with a laser-coolable molecule

Molecular species that are suitable for direct laser cooling are typically considered lost or destroyed if they collide with an ambient temperature vacuum wall. Here, we study surface collisions with aluminum monofluoride (AlF), a laser-coolable molecule that survives this process with unusually high probability. We detect the outgoing AlF molecules from a single wall collision via Doppler-sensitive laser-induced fluorescence spectroscopy, using incoming supersonic (pulsed) and thermochemical (continuous) molecular beams. The angular, velocity and rovibrational level distributions of the outgoing molecules show near-complete thermalisation to the wall in a single collision event. We determine an upper limit to the surface residence time of about 5$~\mu$s, and by monitoring the decay in density of pulses of molecules loaded into a small storage volume, we deduce the surface sticking probability for different materials. For a siloxane-coated metallic surface, the sticking probability of AlF is about 0.015, allowing us to accumulate molecules from the thermochemical source into an ambient temperature storage vessel at densities near $10^{8}~$cm$^{-3}$. This provides a route to compact, portable traps for neutral molecules.

physics.atom-ph

Kinetic modeling of molecular beam formation in a cryogenic buffer-gas cell

Cryogenic buffer-gas cells are widely used to produce cold molecular beams, but the microscopic dynamics governing beam formation remain challenging to model. Here we present fully kinetic simulations of a cryogenic buffer-gas cell using the Direct Simulation Monte Carlo method implemented in the PICLas framework, treating the buffer gas and ablated molecules within a single unified model. We capture characteristic features of cryogenic buffer-gas sources, including plume cooling, directed transport toward the aperture, and the formation of a slow molecular beam, while also resolving energy transfer from the hot ablation plume to the helium buffer gas that is inaccessible to existing approaches relying on the background-gas approximation. Our results demonstrate that fully kinetic simulations can provide detailed insights into buffer-gas cell dynamics and open a route toward a systematic optimization of such sources.

physics.atom-ph