arXiv ScienceSearch

arXiv · 2302.14663

High Sensitive $\alpha$-Fe$_2$O$_3$ Nano-structured Gas Sensor Fabricated through Annealing Technique for Detecting Ethanol

Abstract

On the way to advance the sensing technology, various strategies based on the nano-materials have been introduced to improve the performance of the gas sensors. In this study, we have introduced a facile fabrication procedure for annealing hematite to monitor ethanol gas. Due to large specific area of this conductive platform, more available target molecules (ethanol gas) are detected. To construct this platform, initially, a large scale well-separated iron oxide (hematite) nanostructures are created via an annealing process. The morphology of the nanostructure is optimized through annealing temperature and operating temperature for ethanol gas. The best response for the gas sensor is achieved for hematite nanostructures fabricated through the annealing temperature of 500{\deg}C and the operating temperature of 225$^\circ$C. The fabricated nanostructures is tested in air ambient conditions for various ethanol gas concentrations from 50 to 1000 ppm. The modified sensor exhibited acceptable reproducibility and good selectivity with no interference-effect. To examine the X-ray diffraction patterns of hematite nanostructures at three annealed temperatures, the Rietveld method and FullProf software are used in which the average crystal size has been obtained. Obviously, with increasing the annealing temperature, the average size of the crystals has been increased. The results of ultraviolet-visible spectroscopy show that the energy gap decreased with increasing annealing temperature. The maximum sensing response of hematite flower-like nanostructures is obtained at a concentration of 1000 ppm. Also, the shortest response time is estimated at about 27 seconds for ethanol at a concentration of 200 ppm. The detection limit of this sensor is obtained at 50 ppm.

Explore related subjects

Keep this discovery

BibTeXRIS

Hamed Aleebrahim Dehkordi, Ali Mokhtari, Vishtasb Soleimanian, Mohsen Ghasemi. 2023-02-14. High Sensitive $\alpha$-Fe$_2$O$_3$ Nano-structured Gas Sensor Fabricated through Annealing Technique for Detecting Ethanol. https://arxiv.org/abs/2302.14663

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det