Parallelization of Garfield++ and neBEM to simulate space charge effects in RPCs

Abstract

Numerical simulation of avalanches, saturated avalanches, and streamers can help us understand the detector physics of Resistive Plate Chambers (RPC). 3D Monte Carlo simulation of an avalanche inside an RPC, the transition from avalanche to saturated avalanche to streamer may help the search for the optimum voltage and alternate gas mixtures. This task is dauntingly resource-hungry, especially when space charge effects become important, which often coincides with important regimes of operation of these devices. By modifying the electric field inside the RPC dynamically, the space charge plays a crucial role in determining the response of the detector. In this work, a numerical model has been proposed to calculate the dynamic space-charge field inside an RPC and the same has been implemented in the Garfield++ framework. By modeling space charge as the large number of line charges and using the multithreading technique OpenMP to calculate electric field, drift line, electron gain, and space charge field, it has been possible to maintain time consumption within reasonable limits. For this purpose, a new class, pAvalancheMC has been introduced in Garfield++. The calculations have been successfully verified with those from existing solvers and an example is provided to show the performance of pAvalancheMC. Moreover, the details of the transition of an avalanche into a saturated avalanche have been discussed. The induced charge distribution is calculated for a timing RPC and results are verified with the experiment.

Explore related subjects

Keep this discovery

BibTeXRIS

Tanay Dey, Purba Bhattacharya, Supratik Mukhopadhyay, Nayana Majumdar, Abhishek Seal, Subhasis Chattopadhyay. 2022-11-11. Parallelization of Garfield++ and neBEM to simulate space charge effects in RPCs. https://doi.org/10.1016/j.cpc.2023.108944

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det