arXiv ScienceSearch

arXiv · 2209.02020

Searching for an eco-friendly gas mixture for the ALICE Resistive Plate Chambers

Abstract

The ALICE RPCs are operated with a mixture of 89.7% $C_{2}H_{2}F_{4}$, 10% i-$C_{4}H_{10}$ and 0.3% $SF_{6}$. $C_{2}H_{2}F_{4}$ and $SF_{6}$ are fluorinated greenhouse gases with a high Global Warming Potential (GWP). New European Union regulations have imposed a progressive phase-down of the production and usage of F-gases, aiming to cut down their emission by two thirds in 2030 with respect to 2014. Even though research activities are excluded from these regulations, the phase-down will inevitably increase their price and CERN is also aiming to cut down on its emissions. For these reasons it is crucial to find a more eco-friendly gas mixture for RPCs by the time of the LHC long shutdown 3, foreseen in 2026. Since $C_{2}H_{2}F_{4}$ is the main contributor to the mixture GWP, an extensive R&D process has started to replace it with tetrafluoropropene ($C_{3}H_{2}F_{4}$), due to its chemical similarity with $C_{2}H_{2}F_{4}$ and its low GWP (around 7). Preliminary tests with cosmic rays have shown promising results in terms of detector performance. The next step is to study the long-term behavior of RPCs operated with these new gas mixtures (aging studies). Since this is a subject of interest for all (and not only) the LHC experiments, a collaboration, ECOgas@GIF++, was setup to carry out joint studies. Among others, a small ALICE-like RPC was installed at the Gamma Irradiation Facility at CERN, where they are exposed to a strong radiation field, coming from a 12.5 TBq $^{137}$Cs source, which allows one to simulate many years of operation in a relatively short time. The facility also provides a muon beam at specific times of the year, which can be used to study the detector performance (e.g. efficiency and cluster size) during and after irradiation.

Explore related subjects

Keep this discovery

BibTeXRIS

Luca Quaglia, R. Cardarelli, B. Liberti, E. Pastori, G. Proto, G. Aielli, P. Camarri, A. Di Ciacco, L. Di Stante, R. Santonico, G. Alberghi, D. Boscherini, A. Bruni, L. Massa, A. Polini, M. Romano, L. Benussi, S. Bianco, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo M. Ferrini, G. Saviano, M. Abbrescia, L. Congedo, M. De Serio, G. Galati, G. Pugliese, S. Simone, P. Salvini, A. Samalan, M. Tytgat, N. Zaganidis, J. Eysermans, A. Ferretti, M. Gagliardi, L. Terlizzi, E. Vercellin, P. Dupieux, B. Joly, S. P. Manen, M. Corbetta, R. Guida, B. Mandelli, G. Rigoletti, M. Barroso, M. C. Arena, M. Verzeroli, A. Pastore, R. Aly. 2022-09-05. Searching for an eco-friendly gas mixture for the ALICE Resistive Plate Chambers. https://arxiv.org/abs/2209.02020

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det