arXiv ScienceSearch

arXiv · 2208.11681

Parametric amplification via superconducting contacts in a Ka band niobium pillbox cavity

Abstract

Superconducting parametric amplifiers are commonly fabricated using planar transmission lines with a non-linear inductance provided by either Josephson junctions or the intrinsic kinetic inductance of the thin film. However, Banys et al. [1] reported non-linear behaviour in a niobium pillbox cavity, hypothesising that below Tc, the pair iris-bulk resonator would act as a superconducting contact surface exploiting a Josephson-like non-linearity. This work investigates this effect further by applying Keysight Technologies' Advanced Design System (ADS) to simulate the cavity using an equivalent circuit model that includes a user defined Josephson inductance component. The simulations show that for a resonance centred at nu0 = 30.649 GHz, when two tones (pump and signal) are injected into the cavity, mixing and parametric gain occur. The maximum achievable gain is explored when the resonator is taken to its bifurcation energy. These results are compared to cryogenic measurements where the pump and signal are provided by a Vector Network Analyzer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Valerio Gilles, Danielius Banys, Mark A. McCulloch, Lucio Piccirillo, Thomas Sweetnam. 2022-10-03. Parametric amplification via superconducting contacts in a Ka band niobium pillbox cavity. https://doi.org/10.1007/s10909-022-02891-w

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det