arXiv ScienceSearch

arXiv · 2203.01395

Neutrino mass measurements using cryogenic detectors

Abstract

The determination of the absolute mass scale of neutrinos is one of the most important challenges in Particle Physics. The shape of the endpoint region of $β$-decay and electron capture (EC) spectra depends on the phase space factor, which, in turn, is function of the neutrino mass eigenstates. High energy resolution and high statistics measurements of $β$- and EC spectra are therefore considered a model-independent way for the determination of the neutrino mass scale. Since almost four decades, low temperature microcalorimeters are used for the measurement of low energy $β$- and EC spectra. The first efforts were focused on the development of large arrays for the measurement of the $^{187}$Re $β$-spectrum. In the last ten years, the attention moved to EC of $^{163}$Ho. This choice was mainly motivated by the very good performance which could be achieved with low temperature microcalorimeters enclosing $^{163}$Ho with respect to microcalorimeters with absorber containing $^{187}$Re. The development of low temperature microcalorimeters for the measurement of the finite neutrino mass is discussed and, in particular, the reasons for moving from $^{187}$Re to $^{163}$Ho. The possibility to reach sub-eV sensitivity on the effective electron neutrino mass with $^{163}$Ho, thanks to the multiplexing of large microcalorimeter arrays is demonstrated. In conclusion, an overview on other nuclides which have been proposed as good candidates, motivated by the excellent performance of low temperature microcalorimeters is presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Loredana Gastaldo. 2022-03-02. Neutrino mass measurements using cryogenic detectors. https://doi.org/10.1007/s10909-022-02780-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det