Assessing the Value of Complex Refractive Index and Particle Density for Calibration of Low-Cost Particle Matter Sensor for Size-Resolved Particle Count and PM2.5 Measurements

Abstract

Commercially available low-cost particulate matter (PM) sensors provide output as total or size-specific particle counts and mass concentrations. These quantities are not measured directly but are estimated by the original equipment manufacturers' (OEM) proprietary algorithms and have inherent limitations since particle scattering depends on their composition, size, shape, and complex index of refraction (CRI). Hence, there is a need to characterize and calibrate their performance under a controlled environment. We present calibration algorithms for Plantower PMS A003 sensor as a function of particle size and concentration. A standardized experimental protocol was used to control the PM level, environmental conditions and to evaluate sensor-to-sensor reproducibility. The calibration was based on tests when PMS A003 were exposed to different polydisperse standardized testing aerosols. The results suggested particle size distribution from PMS A003 was shifted compared to reference instrument measures. For calibration of number concentration, linear model without adjusting aerosol properties corrects the raw PMS A003 measurement for specific size bins with normalized mean absolute error within 4.0% of the reference instrument. Although the Bayesian Information Criterion suggests that models adjusting for particle optical properties and relative humidity are technically superior, they should be used with caution as the particle properties used in fitting were within a narrow range for challenge aerosols. The calibration models adjusted for particle CRI and density account for non-linearity in the OEM's mass concentrations estimates and demonstrated lower error. These results have significant implications for using PMS A003 in high concentration environments, including indoor air quality and occupational/industrial exposure assessments, wildfire smoke, or near-source monitoring scenarios.

Explore related subjects

Keep this discovery

BibTeXRIS

Ching-Hsuan Huang, Jiayang He, Elena Austin, Edmund Seto, Igor Novosselov. 2021-06-06. Assessing the Value of Complex Refractive Index and Particle Density for Calibration of Low-Cost Particle Matter Sensor for Size-Resolved Particle Count and PM2.5 Measurements. https://doi.org/10.1371/journal.pone.0259745

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det