arXiv ScienceSearch

arXiv · 2102.12000

Dissecting Sub-Cycle Interference in Photoelectron Holography

Abstract

Multipath holographic interference in strong-field quantum tunnel ionization is key to revealing sub-Angstrom attosecond dynamics for molecular movies. This critical sub-cycle motion is often obscured by longer time-scale effects such as ring-shaped patterns that appear in above-threshold ionization (ATI). In the present work, we overcome this problem by combining two novel techniques in theory and experimental analysis: unit-cell averaging and time-filtering data and simulations. Together these suppress ATI rings and enable an unprecedented highly-detailed quantitative match between strong-field ionization experiments in argon and the Coulomb-quantum orbit strong-field approximation (CQSFA) theory. Velocity map images reveal fine modulations on the holographic spider-like interference fringes that form near the polarization axis. CQSFA theory traces this to the interference of three types of electron pathways. The level of agreement between experiment and theory allows sensitive determination of quantum phase differences and symmetries, providing an important tool for quantitative dynamical imaging in quantum systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nicholas Werby, Andrew S. Maxwell, Ruaridh Forbes, Philip H. Bucksbaum, Carla Figueira de Morisson Faria. 2021-02-24. Dissecting Sub-Cycle Interference in Photoelectron Holography. https://doi.org/10.1103/physreva.104.013109

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Vector Measurements Using Integrated Radio Frequency Atomic Magnetometers

We demonstrate reconstruction of three-dimensional radio-frequency (RF) magnetic-field vectors using a pair of integrated RF atomic magnetometers operated with orthogonal bias-field orientations. A theoretical and experimental analysis identifies a phase-ambiguity dead band that limits reconstruction when the two sensor responses become nearly identical. Measurements performed in an unshielded laboratory environment demonstrate accurate reconstruction of RF magnetic-field orientations and validate the predicted dependence of reconstruction accuracy on signal imbalance. These results establish integrated RF atomic magnetometers as a compact and sensitive platform for directional RF magnetic-field sensing, particularly at low frequencies, and provide a foundation for portable source-localization and field-mapping applications.

physics.atom-ph

Anomalously enhanced lifetimes of low angular momentum Rydberg states in singly charged alkaline-earth metal ions

Trapped ions excited to high-lying electronic states, so-called Rydberg states, open new opportunities for quantum simulation and quantum computing. Generally, the fidelity of quantum coherent operations critically depends on the longevity of Rydberg states. However, scaling laws predict that the lifetimes of Rydberg states in singly charged alkaline-earth metal ions are 16 times shorter, compared to their neutral atom counterparts. Here, we show that this is not generally the case. We report an anomalous lifetime enhancement of certain low angular momentum ionic Rydberg series by factors larger than eight. The anomaly is present at both zero and finite temperature, although it is caused by different mechanisms. At zero temperature, the anomalously enhanced lifetimes are caused by accidental cancellations of the relevant dipole transition matrix elements, while at room temperature the anomaly originates from the enlarged energetic separation of ionic Rydberg levels with respect to neutral-atom levels.

physics.atom-ph

Ytterbium lattice clock with systematic uncertainty of $1.3\times 10^{-18}$ and instability at the $10^{-19}$ level

We report an optical lattice clock based on $^{171}$Yb atoms with a total systematic uncertainty of $1.3\times 10^{-18}$. An in-vacuum buildup cavity was employed to enhance the lattice light power. Differential frequency measurement between two identical clocks facilitates the evaluation of systematic shifts. Synchronous comparison of the two clocks reached a stability level of $2.7\times 10^{-19}$ in an averaging time of 216,000~s. The blackbody radiation (BBR) shield which is placed in vacuum provides a well-characterized BBR environment, enabling an uncertainty contribution of $8.7\times 10^{-19}$ from the BBR Stark shift. Lattice light shifts were measured at different lattice depths $U$, and fitted with a fourth-order polynomial of $U$. The zero-linear-shift frequency $ν_{\mathrm{zero}}$ was determined to be 394 798 260.6(3) MHz. The lattice light shift can be controlled at an uncertainty level of $6.3\times 10^{-19}$ under typical operating conditions. Other systematic shifts have also been evaluated. The two clocks will be used for remote frequency comparisons between Shanghai and Wuhan.

physics.atom-ph