arXiv ScienceSearch

arXiv · 2012.14780

A computational study for tomographic imaging of temperature, water and carbon dioxide concentration in combustion gases using a single tunable diode laser

Abstract

There is a present-day need of optimization of the combustion processes and catalytic efficiency for minimization of emission of pollutants, which can be possible by analyzing the temperature and combustion products distribution in the combustion processes internally. This paper discusses the feasibility of simultaneous 2-D tomographic imaging of temperature and concentrations of CO$_2$ and H$_2$O by scanning a single narrowband laser. The choice of spectroscopic lines of H$_2$O for two-tone temperature measurement is discussed around the wavelength range of 2000 nm. This region is selected as both H$_2$O and CO$_2$ spectral lines have sufficient intensity levels. The pair of wavenumbers (5005.53 and 5003.3 cm$^{-1}$) is found the best of all for temperature and H$_2$O concentration distribution and 5004.36 cm$^{-1}$ is chosen for CO$_2$. To establish the efficacy of different reconstruction algorithms, the phantoms of bimodal and concentric temperature distribution with uniform concentration were tried with four reconstruction techniques. Impressive reconstructions were achieved for distribution of temperature and concentrations of H$_2$O and CO$_2$ for same types of phantoms using Filtered Landweber and Tikhonov regularization methods for 5005.53 and 5003.3 cm$^{-1}$. Initially the imaging was tried using both fanbeam and discrete irregular beam array with 100 and 31 beams respectively. Instead of less number of beams, the later one also shows very promising result.

Explore related subjects

Keep this discovery

BibTeXRIS

Satwik Choudhury, Sandip Pal. 2020-12-29. A computational study for tomographic imaging of temperature, water and carbon dioxide concentration in combustion gases using a single tunable diode laser. https://arxiv.org/abs/2012.14780

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det