arXiv · 2009.04068
Optimization of Electrostatic Quadrupole Profile to Reduce Image Charge Effects
Abstract
Vertical electric fields need to remain orders of magnitude smaller than the horizontal electric field in storage ring electric dipole moment experiments. Otherwise, the coupling with the magnetic dipole moment dominates the spin precession, eventually leading to a false signal. This work presents first quantitative studies regarding electrostatic quadrupole profile optimization, which helps suppressing image beam induced vertical electric fields. Besides the demonstration of the profile optimization, its suppression performance is also studied for various beam offsets and beam size configurations. It is found that with the optimum profile, the vertical electric field can be reduced by two orders of magnitude.
Explore related subjects
Keep this discovery
Selcuk Haciomeroglu. 2020-09-09. Optimization of Electrostatic Quadrupole Profile to Reduce Image Charge Effects. https://arxiv.org/abs/2009.04068