arXiv · 2008.13234
An all-optical intrinsic atomic gradiometer with sub-20 fT/cm/$\sqrt{\rm Hz}$ sensitivity in a 22 $μ$T earth-scale magnetic field
Abstract
In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/$\sqrt{\rm Hz}$ at the finite field strength of 22 $μ$T. The experimental timing sequence can be tuned to the field magnitude of interest. Our one dimensional all-optical gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
A. R. Perry, M. D. Bulatowicz, M. Larsen, T. G. Walker, R. Wyllie. 2020-11-16. An all-optical intrinsic atomic gradiometer with sub-20 fT/cm/$\sqrt{\rm Hz}$ sensitivity in a 22 $μ$T earth-scale magnetic field. https://doi.org/10.1364/oe.408486
Cite the original work for its findings. Save a collection to share your selection of sources.