arXiv ScienceSearch

arXiv · 2007.11151

Liquid-crystal display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems

Abstract

Achromatic, mean-modulated flicker (wherein luminance increments and decrements of equal magnitude are applied, over time, to a test field) is commonly used in both clinical assessment of vision and experimental studies of visual systems. However, presenting flicker on computer-controlled displays is problematic; displays typically introduce luminance artifacts at high flicker frequency or contrast, potentially interfering with the validity of findings. Here, we present a battery of tests used to weigh the relative merits of two displays for presenting achromatic, mean-modulated flicker. These tests revealed marked differences between a new high-performance liquid-crystal display (LCD; EIZO ColorEdge CG247X) and a new consumer-grade LCD (Dell U2415b), despite displays' vendor-supplied specifications being almost identical. We measured displayed luminance using a spot meter and a linearized photodiode. We derived several measures, including spatial uniformity, the effect of viewing angle, response times, Fourier amplitude spectra, and cycle-averaged luminance. We presented paired luminance pulses to quantify the displays' nonlinear dynamics. The CG247X showed relatively good spatial uniformity (e.g., at moderate luminance, standard deviation 2.8% versus U2415b's 5.3%). Fourier transformation of nominally static test patches revealed spectra free of artifacts, with the exception of a frame response. The CG247X's rise and fall times depended on both the luminance from which, and to which, it responded, as is to be generally expected from LCDs. Despite this nonlinear behaviour, we were able to define a contrast and frequency range wherein the CG247X appeared largely artifact-free; the relationship between nominal luminance and displayed luminance was accurately modelled using a causal, linear time-invariant system. This range included contrasts up to 80%, and flicker frequencies up to 30 Hz.

Explore related subjects

Keep this discovery

BibTeXRIS

Luke E Hallum, Shaun L Cloherty. 2020-07-22. Liquid-crystal display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems. https://doi.org/10.1371/journal.pone.0248180

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Platonic brain bridge hypothesis: human brain networks as an architectural prior for omni models

We propose the Platonic brain bridge hypothesis: omni models, which process video, audio and text jointly like the brain, converge on brain-like representations, and the correspondence is bidirectional. From model to brain, brain-likeness of seven omni models is stable across participants, and our encoding models on their internal hidden states rank first on the Algonauts 2025 out-of-distribution leaderboard. From brain to model, three contributions follow. Brain-MoE gives seven cortical networks one brain-pretrained expert each and raises held-out accuracy in all 15 model-benchmark pairs by 6.42 percentage points on average. Brain-AVQA builds questions from video clips labelled by the most responsive brain network; the real network-to-expert map exceeds shuffled maps in-domain on all three models. Brain-Scope uses sparse autoencoders to localize the correspondence to a small subset whose removal weakens brain prediction in all three bases tested. Human brain networks are therefore a usable architectural prior for omni models.

q-bio.NC

Degeneracy along the sensorimotor hierarchy: motor control within a framework larger than redundancy

Motor control has described the surplus of solutions available to the nervous system as redundancy, a term that names duplication: interchangeable elements, robust to loss but incapable of differential adaptation. Biology has had a second term for twenty-five years. Degeneracy names elements that are not interchangeable and are nonetheless isofunctional with respect to a given output, and it supports adaptability, since non-identical elements necessarily diverge in some context. Circuit neuroscience has relabeled its own results accordingly, while motor control has kept the older vocabulary. Neuromechanical models, by placing a spinal circuit in the loop with a musculoskeletal apparatus, bring the two traditions onto the same class of objects. We restate the Edelman and Tononi distinction for sensorimotor systems and derive an operational requirement: not the existence of multiple solutions, but their divergence in contexts they were not selected for. Three influential studies each meet part of that requirement and none meets all. We then argue that degeneracy and redundancy coexist along the sensorimotor hierarchy in a proportion that varies continuously, and that this proportion is measurable: computing degeneracy twice for the same configuration, once with muscle activation as the output and once with the movement produced, isolates what the musculoskeletal apparatus contributes. Five predictions follow, with the single outcome that would refute the proposal. We set out the adaptations the measurement requires in a nonlinear, non-stationary, closed-loop system, and what changes for motor control once solutions are no longer assumed equivalent: the question shifts from which rule selects a command to what the repertoire of the system still allows.

q-bio.NC

pyAvalanches: A Python Package for Analyzing Spatiotemporal Propagation in Neuronal Avalanches

The analysis of neuronal avalanches offers insights into brain dynamics utilizing the framework of criticality, but the reproducibility and comparability of studies are limited by the use of fragmented, lab-specific scripts. To address this issue, we introduce pyAvalanches, an open-source Python package providing a standardized, end-to-end pipeline for avalanche analysis from electrophysiological recordings (e.g., electroencephalography-EEG). Starting from the detection of neuronal avalanches the package provides their core statistical characterization, including size and duration distributions. Beyond this, the main aim of pyAvalanches is to characterize the spatiotemporal organization of activity propagation during avalanches. To this end, the core innovation of pyAvalanches is the compuation of Avalanche Transition Matrices (ATMs) to map spatiotemporal propagation patterns. Building on this, the package derives network-based metrics from the ATMs, bridging the study of the topology and organization of the underlying dynamical interactions with network neuroscience adopting the framework of neuronal avalanches. The entire workflow is encapsulated in a modular and scikit-learn compatible architecture. We demonstrate the utility of pyAvalanches through an illustrative group-level analysis on a public resting-state EEG dataset, comparing propagation patterns across different clinical populations. By providing a user-friendly, tested, and extensible tool, pyAvalanches facilitates reproducible research, enables the development of novel avalanche-based biomarkers, and makes complex avalanche analysis accessible to a broader scientific community. The package is fully documented and distributed via the Python Package Index (PyPI).

q-bio.NC