arXiv ScienceSearch

arXiv · 2007.00898

Non-Gaussianity Detection of EEG Signals Based on a Multivariate Scale Mixture Model for Diagnosis of Epileptic Seizures

Abstract

Objective: The detection of epileptic seizures from scalp electroencephalogram (EEG) signals can facilitate early diagnosis and treatment. Previous studies suggested that the Gaussianity of EEG distributions changes depending on the presence or absence of seizures; however, no general EEG signal models can explain such changes in distributions within a unified scheme. Methods: This paper describes the formulation of a stochastic EEG model based on a multivariate scale mixture distribution that can represent changes in non-Gaussianity caused by stochastic fluctuations in EEG. In addition, we propose an EEG analysis method by combining the model with a filter bank and introduce a feature representing the non-Gaussianity latent in each EEG frequency band. Results: We applied the proposed method to multichannel EEG data from twenty patients with focal epilepsy. The results showed a significant increase in the proposed feature during epileptic seizures, particularly in the high-frequency band. The feature calculated in the high-frequency band allowed highly accurate classification of seizure and non-seizure segments [area under the receiver operating characteristic curve (AUC) = 0.881] using only a simple threshold. Conclusion: This paper proposed a multivariate scale mixture distribution-based stochastic EEG model capable of representing non-Gaussianity associated with epileptic seizures. Experiments using simulated and real EEG data demonstrated the validity of the model and its applicability to epileptic seizure detection. Significance: The stochastic fluctuations of EEG quantified by the proposed model can help detect epileptic seizures with high accuracy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Akira Furui, Ryota Onishi, Akihito Takeuchi, Tomoyuki Akiyama, Toshio Tsuji. 2020-07-02. Non-Gaussianity Detection of EEG Signals Based on a Multivariate Scale Mixture Model for Diagnosis of Epileptic Seizures. https://doi.org/10.1109/tbme.2020.3006246

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Carrier Rydberg Atomic Quantum Receivers with Enhanced Bandwidth Feature for Communication and Sensing

Rydberg atomic quantum receivers (RAQRs) have attracted significant attention in recent years due to their ultra-high sensitivity. Although capable of precisely detecting the amplitude and phase of weak signals, conventional RAQRs face inherent limitations in accurately receiving wideband RF signals, due to the discrete nature of atomic energy levels and their intrinsic instantaneous bandwidth constraints. These limitations hinder their direct application to multi-carrier communication and sensing. To address this issue, this paper proposes a multi-carrier Rydberg atomic quantum receiver (MC-RAQR) structure with five energy levels. We derive the amplitude and phase of the MC-RAQR and extract the baseband electrical signal for signal processing. In terms of multi-carrier communication and sensing, we analyze the channel capacity and accuracy of angle of arrival (AoA) and distance parameters, respectively. Numerical results validate our proposed model, showing that the MC-RAQR can achieve up to a bandwidth of 11.7 MHz, which is 17-fold larger than the conventional RAQRs. As a result, the channel capacity and the resolution for multi-target sensing are improved significantly. Specifically, the channel capacity of MC-RAQR is 110-fold and 2.8-fold larger than the classical RF receivers and RAQRs, respectively. For sensing performance, the RMSE of AoA estimation for MC-RAQR exhibits 7.6-fold reduction, compared with the conventional RAQRs. Furthermore, the RMSE of distance estimation is $634$-fold smaller than that of the root-CRB of classical RF receivers, showing the superior performance of the MC-RAQR. This demonstrates its compatibility with waveforms such as orthogonal frequency-division multiplexing (OFDM) and its significant advantages for multi-carrier signal reception.

eess.SP

Channel Estimation in MIMO Systems Aided by Microwave Linear Analog Computers (MiLACs)

Microwave linear analog computers (MiLACs) have recently emerged as a promising solution for future gigantic multiple-input multiple-output (MIMO) systems, enabling beamforming with greatly reduced hardware and computational cost. However, channel estimation for MiLAC-aided systems remains an open problem. Conventional least squares (LS) and minimum mean square error (MMSE) estimation rely on intensive digital computation, which undermines the computational advantage offered by MiLACs. In this letter, we propose efficient LS and MMSE channel estimation schemes for MiLAC-aided MIMO systems. By designing the training precoder and combiner implemented by lossless and reciprocal MiLACs, the proposed schemes perform LS and MMSE estimation in the analog domain, leaving only simple digital scaling. They achieve identical estimation performance to their digital counterparts while significantly reducing computational complexity. Numerical results verify the effectiveness of the proposed schemes.

eess.SP

Joint Subcarrier Phase Recovery for Nonlinearity Mitigation

We propose a low-complexity phase recovery scheme that simultaneously mitigates laser phase noise and fiber nonlinearity across several subcarriers. In a long single-span link with Raman amplification, the scheme achieves 0.9 dB gain with 99 real multiplications per complex symbol.

eess.SP