Abstract
In contrast to current efforts to quantify the radiation pressure of light using nano-micromechanical resonators in cryogenic conditions, we proposed and experimentally demonstrated the radiation pressure measurement in ambient conditions by utilizing a macroscopic mechanical longitudinal oscillator with an effective mass of the order of 20 g. The light pressure on a mirror attached to the oscillator was recorded in a Michelson interferometer and results showed, within the experimental accuracy of 3.9%, a good agreement with the harmonic oscillator model without free parameters.
Explore related subjects
Keep this discovery
Mikko Partanen, Hyeonwoo Lee, Kyunghwan Oh. 2020-05-24. Radiation pressure measurement using a macroscopic oscillator in an ambient environment. https://doi.org/10.1038/s41598-020-77295-5