arXiv ScienceSearch

arXiv · 2004.01715

Newtonian gravitational constant measurement. All atomic variables become extreme when using a source mass consisting of 3 or more parts

Abstract

Atomic interferometry methods used to measure the Newtonian gravitational constant. To improve the accuracy, one should measure the phase of an atomic interferometer at extreme values of atomic vertical velocities and coordinates. Owing to symmetry, the horizontal components of atomic velocities and coordinates are also extreme. We propose using a source mass consisting of 3 or more parts, since only in this case one can find such an arrangement of parts that all atomic variables become extreme. Nonlinear dependences of the phase on the uncertainties of atomic positions and velocities near those extreme values required us to modify the expression for the phase relative standard deviation (RSD). Moreover, taking into account nonlinear terms in the phase dependence on the atomic coordinates and velocities leads to a phase shift. In the last experiment to measure the Newtonian gravitational constant by atomic interferometry, this shift was not included. We took the shift into account, got a value of 199ppm for it, and this leads to a decrease in the value of the Newton constant by 0.02%. In addition, we showed that at equal sizes of the atomic cloud in the vertical and horizontal directions, as well as at equal atomic vertical and transverse temperatures, systematic errors due to the finite size and temperature of the cloud disappear. The calculation also showed that when using the 13-ton source mass proposed recently, the measurement accuracy can reach 17ppm for a source mass consisting of 4 quarters. We assumed that the source mass consisting of a set of cylinders is used for measurements. We have obtained a new analytical expression for the gravitational field of a homogeneous cylinder.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B. Dubetsky. 2021-02-09. Newtonian gravitational constant measurement. All atomic variables become extreme when using a source mass consisting of 3 or more parts. https://doi.org/10.1088/1681-7575%2Fabc92e

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Vector Measurements Using Integrated Radio Frequency Atomic Magnetometers

We demonstrate reconstruction of three-dimensional radio-frequency (RF) magnetic-field vectors using a pair of integrated RF atomic magnetometers operated with orthogonal bias-field orientations. A theoretical and experimental analysis identifies a phase-ambiguity dead band that limits reconstruction when the two sensor responses become nearly identical. Measurements performed in an unshielded laboratory environment demonstrate accurate reconstruction of RF magnetic-field orientations and validate the predicted dependence of reconstruction accuracy on signal imbalance. These results establish integrated RF atomic magnetometers as a compact and sensitive platform for directional RF magnetic-field sensing, particularly at low frequencies, and provide a foundation for portable source-localization and field-mapping applications.

physics.atom-ph

Anomalously enhanced lifetimes of low angular momentum Rydberg states in singly charged alkaline-earth metal ions

Trapped ions excited to high-lying electronic states, so-called Rydberg states, open new opportunities for quantum simulation and quantum computing. Generally, the fidelity of quantum coherent operations critically depends on the longevity of Rydberg states. However, scaling laws predict that the lifetimes of Rydberg states in singly charged alkaline-earth metal ions are 16 times shorter, compared to their neutral atom counterparts. Here, we show that this is not generally the case. We report an anomalous lifetime enhancement of certain low angular momentum ionic Rydberg series by factors larger than eight. The anomaly is present at both zero and finite temperature, although it is caused by different mechanisms. At zero temperature, the anomalously enhanced lifetimes are caused by accidental cancellations of the relevant dipole transition matrix elements, while at room temperature the anomaly originates from the enlarged energetic separation of ionic Rydberg levels with respect to neutral-atom levels.

physics.atom-ph

Ytterbium lattice clock with systematic uncertainty of $1.3\times 10^{-18}$ and instability at the $10^{-19}$ level

We report an optical lattice clock based on $^{171}$Yb atoms with a total systematic uncertainty of $1.3\times 10^{-18}$. An in-vacuum buildup cavity was employed to enhance the lattice light power. Differential frequency measurement between two identical clocks facilitates the evaluation of systematic shifts. Synchronous comparison of the two clocks reached a stability level of $2.7\times 10^{-19}$ in an averaging time of 216,000~s. The blackbody radiation (BBR) shield which is placed in vacuum provides a well-characterized BBR environment, enabling an uncertainty contribution of $8.7\times 10^{-19}$ from the BBR Stark shift. Lattice light shifts were measured at different lattice depths $U$, and fitted with a fourth-order polynomial of $U$. The zero-linear-shift frequency $ν_{\mathrm{zero}}$ was determined to be 394 798 260.6(3) MHz. The lattice light shift can be controlled at an uncertainty level of $6.3\times 10^{-19}$ under typical operating conditions. Other systematic shifts have also been evaluated. The two clocks will be used for remote frequency comparisons between Shanghai and Wuhan.

physics.atom-ph