arXiv ScienceSearch

arXiv · 2003.05281

Wafer-Bonded Surface Plasmon Waveguide Biosensors with In-Plane Microfluidic Interfaces

Abstract

Biosensors exploiting long-range surface plasmon polariton (LRSPP) waveguides comprised of Au stripes embedded in Cytop with integrated and encapsulated microfluidic channels are fabricated and demonstrated. A fabrication approach was devised where the lower cladding and recessed Au stripes are fabricated on a Si substrate, and the upper cladding and microfluidic channels are fabricated on a glass substrate, followed by wafer bonding to assemble the wafers into complete structures. The bond is centered over the full length of the optical path, yet no evidence of optical scattering or excess loss due to the bond could be observed, and no evidence of a bonding interface could be discerned from high-magnification cross-sectional images. We also demonstrate wafer-scale fabrication of in-plane microfluidic inlets and outlets, along with a fixture for fluidic edge coupling that provides sealed interfaces to external fluidic tubing and components. In-plane microfluidic interfaces are automatically defined along chip facets upon wafer dicing, precluding the need to drill through holes in lids. The performance of the chips was assessed by measuring the attenuation of LRSPPs on fully cladded reference waveguides, on waveguides passing through microfluidic channels, and by measuring the response of sensors to changes in refractive index produced by injecting various sensing solutions. Our fabrication approach based on wafer bonding and in-plane fluidic interfacing is compelling for low-cost high-volume manufacturing.

Explore related subjects

Keep this discovery

BibTeXRIS

Muhammad Asif, Oleksiy Krupin, Wei Ru Wong, Zohreh Hirbodvash, Ewa Lisicka-Skrzek, Choloong Hahn, R. Niall Tait, Pierre Berini. 2020-03-04. Wafer-Bonded Surface Plasmon Waveguide Biosensors with In-Plane Microfluidic Interfaces. https://doi.org/10.1088/1361-6439/ab92e9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det