MOSARIX: Progress Report

Abstract

MOSARIX is a collaborative project between three research group in Sorbonne University to build a x-ray spectrometer (2-5 keV) portable to large scale facilities with high efficiency and good resolution. X-ray spectroscopy and coincidences experiment are planned. A prototype with a single HADP crystal with von Hamos geometry has been tested (resolution and efficiency). A fast time and position detector has been realized (patent and publication).We plan to build the spectrometer with 8 HADP (or 4) crystals under Helium atmosphere using a TimePix3 or a CCD camera. MOSARIX is a project of an x-ray spectrometer in the tender x-ray domain (2-5 keV) with high efficiency, allowing performing x-ray emission and coincidences (or covariance mapping) experiments using synchrotron radiation, XFEL, the future installation SPIRAL2/GANIL or CRYRING/FAIR. It involves 2 groups at LCPMR (Francis PENENT and Marc SIMON) and one group at INSP (Dominique VERNHET). The coincidences/covariance measurements will be between x-ray photons and ions or electrons. It would be the first time for such coincidences with energy-resolved photons. The spectrometer will be portable and will be brought to the different large-scale facilities. MOSARIX is a multi-crystal HAPG von Hamos spectrometer optimized for the 2-5 keV photon energy range. Its resolving power E/DE will be 4000. It will be equipped with a fast time and position sensitive detection system, allowing performing coincidences, or with a CCD camera. I. Scientific case and some possible experiments The accelerated development of x-ray sources, as 3 rd generation synchrotrons (and recent upgrades) or free-electron lasers, has opened new opportunities to investigate new phenomena by means of photoelectron and Auger spectroscopy, electron-ion coincidence techniques and x-ray emission. However, several processes of high scientific interests are still hard to measure; some of them require the measurement of photons with high efficiency, high resolution and even sometimes in coincidence mode. This is the purpose of MOSARIX development. As an example, we propose to revisit Resonance-Enhanced X-ray Multiple Ionization (REXMI) 1 with a significant amelioration of the detection of photons, i.e. measuring the photons not only with high efficiency and high resolution but also in coincidence with ions or electrons. This will allow accessing the involved intermediate states and obtaining a clearer image of the dynamic of the multiple ionization process. MOSARIX can also be used for the investigation of very low cross-section phenomena such as attosecond electron dynamics 2 and High-Energy Resolution Off-Resonant Spectroscopy (HEROS) 3,4. X-ray spectroscopy has also proved to be a very powerful tool to investigate quantum dynamics in heavy ions collisions with matter of whatever nature, dilute or condensed 5-7. A

Explore related subjects

Keep this discovery

BibTeXRIS

Iyas Ismail, Marc Simon, Francis Penent. 2020-03-11. MOSARIX: Progress Report. https://arxiv.org/abs/2003.05177

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det