arXiv ScienceSearch

arXiv · 1912.06178

Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC

Abstract

The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large ($\sim$O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented.

Explore related subjects

Keep this discovery

BibTeXRIS

G. Abbiendi, J. Alcaraz Maestre, A. Álvarez Fernández, B. Álvarez González, N. Amapane, I. Bachiller, J. M. Barcala, L. Barcellan, C. Battilana, M. Bellato, G. Bencze, M. Benettoni, N. Beni, A. Benvenuti, L. C. Blanco Ramos, A. Boletti, A. Bragagnolo, J. A. Brochero Cifuentes, V. Cafaro, A. Calderon, E. Calvo, A. Cappati, R. Carlin, C. A. Carrillo Montoya, F. R. Cavallo, J. M. Cela Ruiz, M. Cepeda, M. Cerrada, B. Chazin Quero, P. Checchia, L. Ciano, N. Colino, D. Corti, G. Cotto, J. Cuevas, M. Cuffiani, G. M. Dallavalle, D. Dattola, B. De La Cruz, P. DeRemigis, C. Erice Cid, F. Fabbri, A. Fanfani, D. Fasanella, C. F. Bedoya, J. F. de Trocóniz, P. Fernandez Manteca, J. Fernández Menéndez, J. P. Fernández Ramos, S. Folgueras, M. C. Fouz, D. Francia Ferrero, J. García Romero, F. Gasparini, U. Gasparini, S. Ghosh, V. Giordano, F. Gomez Casademunt, F. Gonella, I. González Caballero, J. R. González Fernández, O. González López, S. Goy López, A. Gozzelino, A. Griggio, G. Grosso, C. Guandalini, L. Guiducci, M. Gulmini, T. Hebbeker, C. Heidemann, J. M. Hernández, K. Hoepfner, F. Iemmi, R. Isocrate, M. I. Josa, B. Kiani, S. Lacaprara, S. Lo Meo, S. Marcellini, M. Margoni, J. Marín, C. Mariotti, I. Martín Martín, J. J. Martínez Morales, C. Martínez Rivero, S. Maselli, G. Masetti, A. T. Meneguzzo, M. Merschmeyer, G. Mocellin, L. Modenese, A. Molinero, J. Molnar, F. Montecassiano, D. Moran, J. J. Navarrete, F. Navarria, Á. Navarro Tobar, J. C. Oller. 2019-12-12. Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC. https://doi.org/10.1088/1748-0221/14/12/c12010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det