Study of bremsstrahlung radiation coming from a transmission type x-ray generator and its application on EDXRF technique

Abstract

We have demonstrated the use of the bremsstrahlung radiation in energy dispersive x-ray fluorescence technique as a tool to perform non-destructive elemental analysis of solid samples employed in inter-disciplinary science research. The bremsstrahlung radiation can be taken from a small, portable, transmission type x-ray generator. As our knowledge goes, till date, this is the first attempt to generate bremsstrahlung spectrum theoretically from a portable transmission type x-ray generator and compared it with the actual observation. Theoretically generated bremsstrahlung spectra are also found to be in good agreement with the experimentally observed spectra obtained with various operating anode voltages of the x-ray generator. A computer program has been developed utilizing few atomic parameters to obtain the elemental concentrations in the sample by a single run using the whole bremsstrahlung. The knowledge of incoming x-ray flux, geometry of experimental arrangements is not required in this technique. To validate the technique, we have taken two samples: an Indian one rupee coin of the year 2000 and a NIST made brass sample, whose compositions are well known. We used these samples to expose to the bremsstrahlung radiation, produced by the operating anode voltages 20, 25, and 30 KV. The relative concentrations of different elements are determined, which is in good agreement with the earlier results.

Explore related subjects

Keep this discovery

BibTeXRIS

Soumya Chatterjee, Sumana Ghosh, D. Mitra. 2019-11-23. Study of bremsstrahlung radiation coming from a transmission type x-ray generator and its application on EDXRF technique. https://arxiv.org/abs/1911.10396

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det