arXiv ScienceSearch

arXiv · 1904.12656

Enhancing the Resolution Limits of Spectral Interferometric Measurements with Swept-Wavelength Interrogation by Means of a Reference Interferometer

Abstract

An approach for compensating the influence of the interrogator noises on the readings of interferometric sensors, interrogated by means of spectral interferometry with wavelength tuning is proposed. Both theoretical analysis and a proof-of-principle experiment were performed for the example of extrinsic Fabry-Perot interferometers (EFPI). Two schemes, comprising of a signal and a reference interferometers, switched in different optical channels of the interrogating unit, were proposed. The approach is based on the fact that the fluctuations of some of the interrogator parameters produce correlated fluctuations of the reference and signal interferometers optical path differences (OPD) measured values. The fluctuations of the reference interferometers measured OPD can be subtracted from the measured OPD of the signal interferometer. The fluctuations of different parameters of the interrogator are considered, the correlation properties of the produced noises of the measured OPD values are demonstrated. The first scheme contains two interferometers with similar parameters and enabled a three-fold resolution improvement in the performed experiments, when the difference of the interferometers OPDs was varied within about 10 nm. The second scheme contains two interferometers with OPDs difference such that all interrogator fluctuations, except for the dominating one produce uncorrelated OPD errors. With the second scheme a two-fold resolution improvement was experimentally demonstrated, when the interferometers OPDs difference was varied within more than 1 \mum. The proposed approach can be used for improving the resolution of interferometric sensors with relatively large OPDs (greater than 200-300 \mum), which can be advantageous for remote materials and surface inspection.

Explore related subjects

Keep this discovery

BibTeXRIS

Nikolai Ushakov, Alexandr Markvart, Leonid Liokumovich. 2019-04-25. Enhancing the Resolution Limits of Spectral Interferometric Measurements with Swept-Wavelength Interrogation by Means of a Reference Interferometer. https://doi.org/10.1364/ao.54.006029

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det