arXiv · 1904.11642
Ultra-low noise magnetic field for quantum gases
Abstract
Ultra-low noise magnetic field is essential for many branches of scientific research. Examplesinclude experiments conducted on ultra-cold atoms, quantum simulations, as well as precisionmeasurements. In ultra-cold atom experiments specifically, a bias magnetic field will be oftenserved as a quantization axis and be applied for Zeeman splitting. As atomic states areusually sensitive to magnetic fields, a magnetic field characterized by ultra-low noise as wellas high stability is typically required for experimentation. For this study, a bias magneticfield is successfully stabilized at 14.5G, with the root mean square (RMS) value of the noisereduced to 18.5{\mu}G (1.28ppm) by placing{\mu}-metal magnetic shields together with a dynamicalfeedback circuit. Long-time instability is also regulated consistently below 7{\mu}G. The level ofnoise exhibited in the bias magnetic field is further confirmed by evaluating the coherencetime of a Bose-Einstein condensate characterized by Rabi oscillation. It is concluded thatthis approach can be applied to other physical systems as well.
Explore related subjects
Keep this discovery
Xiao-Tian Xu, Zong-Yao Wang, Rui-Heng Jiao, Chang-Rui Yi, Wei Sun, Shuai Chen. 2019-04-26. Ultra-low noise magnetic field for quantum gases. https://doi.org/10.1063/1.5087957
Cite the original work for its findings. Save a collection to share your selection of sources.