Evaluation of central corneal thickness in keratoconus and normal corneas during air puff indentation

Abstract

Purpose: This study aimed to investigate the actual changes of central corneal thickness (CCT) in keratoconus and normal corneas during air puff indentation, by using corneal visualization Scheimpflug technology (Corvis ST). Methods: A total of 32 keratoconic eyes and 46 normal eyes were included in this study. Three parameters of CCTinitial, CCTfinal and CCTpeak were selected to represent the CCT at initial time, final time and highest corneal concavity, respectively, during air puff indentation. Wilcoxon signed rank test (paired sample test) was used to assess the differences between these 3 parameters in both keratoconus and normal groups. Univariate linear regression analysis was performed to determine the effect of CCTinitial on CCTpeak and CCTfinal, as well as the impact of air puff force on CCT in each group. Receiver operating characteristic (ROC) curves were constructed to evaluate the discriminative ability of the 3 parameters. Results: The results demonstrated that CCTpeak and CCTfinal were significantly decreased (p<0.01) compared to CCTinitial in both keratoconus and normal groups. Regression analysis indicated a significant positive correlation between CCTpeak and CCTinitial in normal cornea group (R2=0.337, p<0.01), but not in keratoconus group (R2=0.029, p=0.187). Likewise, regression models of air puff force and CCT revealed the different patterns of CCT changes between keratoconus and normal cornea groups. Furthermore, ROC curves showed that CCTpeak exhibited the greatest AUC (area under ROC curve) of 0.940, with accuracy, sensitivity and specificity of 94.9%, 87.5% and 100%, respectively. Conclusions: CCT may change during air puff indentation, and is significantly different between keratoconus and normal cornea groups. The changing pattern is useful for the diagnosis of keratoconus, and lays the foundation for corneal biomechanics.

Explore related subjects

Keep this discovery

BibTeXRIS

Dan Lin, Lei Tian, Chenglang Yuan, Wenxiu Shi, Like Wang, Yongjin Zhou. 2019-01-07. Evaluation of central corneal thickness in keratoconus and normal corneas during air puff indentation. https://arxiv.org/abs/1901.01772

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph