arXiv · 1812.11426
Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam
Abstract
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
H. Abramowicz, A. Abusleme, K. Afanaciev, Y. Benhammou, O. Borysov, M. Borysova, I. Bozovic- Jelisavcic, W. Daniluk, D. Dannheim, M. Demichev, K. Elsener, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, M. Hempelb, H. Henschel, M. Idzik, A. Ignatenkoc, A. Ishikawa, A. Joffe, G. Kacarevic, S. Kananov, O. Karachebanb, W. Klempt, S. Kotov, J. Kotula, U. Kruchonak, Sz. Kulis, W. Lange, J. Leonard, T. Lesiak, A. Levy, I. Levy, L. Linssen, W. Lohmann, J. Moron, A. Moszczynski, A. T. Neagu, B. Pawlik, T. Preda, A. Sailer, B. Schumm, S. Schuwalowd, 1E. Sicking, K. Swientek, B. Turbiarz, N. Vukasinovic, T. Wojton, H. Yamamoto, L. Zawiejski, I. S. Zgura, A. Zhemchugov. 2019-10-25. Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam. https://doi.org/10.1140/epjc%2Fs10052-019-7077-9
Cite the original work for its findings. Save a collection to share your selection of sources.