Performance of CMOS pixel sensor prototypes in ams H35 and aH18 technology for the ATLAS ITk upgrade

Abstract

Pixel sensors based on commercial high-voltage CMOS processes are an exciting technology that is considered as an option for the outer layer of the ATLAS inner tracker upgrade at the High Luminosity LHC. Here, charged particles are detected using deep n-wells as sensor diodes with the depleted region extending into the silicon bulk. Both analog and digital readout electronics can be added to achieve different levels of integration up to a fully monolithic sensor. Small scale prototypes using the ams CMOS technology have previously demonstrated that it can achieve the required radiation tolerance of $10^{15}~\text{n}_\text{eq}/\text{cm}^2$ and detection efficiencies above $99.5~\%$. Recently, large area prototypes, comparable in size to a full sensor, have been produced that include most features required towards a final design: the H35demo prototype produced in ams H35 technology that supports both external and integrated readout and the monolithic ATLASPix1 pre-production design produced in ams aH18 technology. Both chips are based on large fill-factor pixel designs, but differ in readout structure. Performance results for H35DEMO with capacitively-coupled external readout and first results for the monolithic ATLASPix1 are shown.

Explore related subjects

Keep this discovery

BibTeXRIS

Moritz Kiehn, Francesco Armando Di Bello, Mathieu Benoit, Raimon Casanova Mohr, Hucheng Chen, Kai Chen, Sultan D. M. S., Felix Ehrler, Didier Ferrere, Dylan Frizell, Sergio Gonzalez Sevilla, Giuseppe Iacobucci, Francesco Lanni, Hongbin Liu, Claudia Merlassino, Jessica Metcalfe, Antonio Miucci, Ivan Peric, Mridula Prathapan, Rudolf Schimassek, Mateus Vicente Barreto, Thomas Weston, Eva Vilella Figueras, Alena Weber, Michele Weber, Winnie Wong, Weihao Wu, Ettore Zaffaroni, Hui Zhang, Matt Zhang. 2018-07-16. Performance of CMOS pixel sensor prototypes in ams H35 and aH18 technology for the ATLAS ITk upgrade. https://doi.org/10.1016/j.nima.2018.07.061

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det