arXiv ScienceSearch

arXiv · 1807.05680

High Rate RPC detector for LHC

Abstract

The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\ {\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($\eta$) region of the forward muon spectrometer ($2.4 > |\eta| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $\eta$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.

Explore related subjects

Keep this discovery

BibTeXRIS

F. Lagarde, A. Fagot, M. Gul, C. Roskas, M. Tytgat, N. Zaganidis, S. Fonseca De Souza, A. Santoro, F. Torres Da Silva De Araujo, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov, A. Petrov, S. J. Qian, D. Han, W. Yi, C. Avila, A. Cabrera, C. Carrillo, M. Segura, S. Aly, Y. Assran, A. Mahrous, A. Mohamed, C. Combaret, M. Gouzevitch, G. Grenier, I. B. Laktineh, H. Mathez, L. Mirabito, K. Shchablo, I. Bagaturia, D. Lomidze, I. Lomidze, L. M. Pant, V. Bhatnagar, R. Gupta, R. Kumari, M. Manisha, J. B. Singh, V. Amoozegar, B. Boghrati, H. Ghasemy, S. Malmir, M. Mohammadi Najafabadi, M. Abbrescia, A. Gelmi, G. Iaselli, S. Lezki, G. Pugliese, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, S. Buontempo, A. Crescenzo, G. Galati, F. Fienaga, I. Orso, L. Lista, S. Meola, P. Paolucci, E. Voevodina, A. Braghieri, P. Montagna, M. Ressegotti, C. Riccardi, P. Salvini, P. Vitulo, S. W. Cho, S. Y. Choi, B. Hong, K. S. Lee, J. H. Lim, S. K. Park, J. Goht, T. J. Kim, S. Carrillo Moreno, O. Miguel Colin, F. Vazquez Valencia, S. Carpinteyro Bernardino, J. Eysermans, I. Pedraza, C. Uribe Estrada, R. Reyes-Almanza, M. C. Duran-Osuna, G. Ramirez-Sanchez, A. Sanchez-Hernandez, R. I. Rabadan-Trejo, H. Castilla-Valdez, A. Radi, H. Hoorani, S. Muhammad. 2018-07-16. High Rate RPC detector for LHC. https://doi.org/10.1088/1748-0221/14/10/c10037

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det