Abstract

A feasibility study of the megavoltage (MV) computed tomography (CT) for imaging large cargos has been performed. The MV cargo CT system has imaging field of view of 3.25m in diameter. The system design includes a compact x-ray source and detectors that are already used in existing MV cargo radiography systems. Although compact x-ray sources provide limited x-ray output, it is shown that this output is sufficient to perform CT imaging of large cluttered cargo contents for which MV radiography may be inconclusive. The scan time is 60sec. at the x-ray dose levels lower than the permitted limit of 5mGy. A steel tank phantom with 2m diameter including different materials was used. The MV CT images were generated at 3.5MV, 6MV, and 9MV beam energies. The materials were separated based on their CT numbers as well as using dual energy subtraction method. The materials with close densities and x-ray attenuations such as W and U were reliably separated and quantified based on their measured CT numbers. The boundary conditions for the system design were determined including scan time, radiation dose, maximum object thicknesses, and spatial resolution. Based on the findings of this feasibility study, it is concluded that the MV cargo CT system with large field of view can be developed based on existing technology already used in MV cargo radiography. Such a CT system can be extremely useful as adjunct to existing MV radiography on resolving the special cases that cannot be resolved conclusively with radiography alone.

Explore related subjects

Keep this discovery

BibTeXRIS

Polad M. Shikhaliev. 2018-05-11. Computed Tomography imaging of large cargos. https://arxiv.org/abs/1805.04608

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det