arXiv ScienceSearch

arXiv · 1711.09458

The Benefit of Wide Energy Range Spectrum Acquisition During Sputter Depth Profile Measurements

Abstract

Thin film systems are often analysed by using sputter depth profiling. First the sample gets eroded by inert gas ion impact during sputter depth profiling. Then the elemental composition of the freshly unveiled surface is determined by using a surface sensitive analytical method as AES or XPS, for instance. This way the depth distributions of the elements are recorded as a function of sputter time. The time to record the spectral data in a certain sputter depth is kept as short as possible to avoid recontamination of the freshly sputtered surface by adsorption of gas particles from the vacuum during the measurement. Therefore in every sputter depth only those spectral regions are recorded, which belong to the elements expected to be in the sample. But in case the sample composition is entirely unknown, it is indispensable to measure wide energy range spectra. By this approach the depth distributions of all elements are estimated, which are detectable by the used analytical method. The measurement of wide energy range spectra during sputter depth profile acquisition is promising for samples, which are very insulating. If the surface potential varies in different sputter depths, the elemental peaks are shifted in an unpredictable way. If wide energy range spectra are recorded, the energy scale can be re-adjusted afterwards and the data can be re-evaluated. Both use cases are demonstrated exemplarily by sputter depth profile measurements.

Explore related subjects

Keep this discovery

BibTeXRIS

Uwe Scheithauer. 2017-11-26. The Benefit of Wide Energy Range Spectrum Acquisition During Sputter Depth Profile Measurements. https://arxiv.org/abs/1711.09458

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det