Abstract

The foreseen upgrade of the LHC to its high luminosity phase (HL-LHC), will maximize the physics potential of the facility. The upgrade is expected to increase the instantaneous luminosity by a factor of 5 and deliver an integrated luminosity of 3000 fb-1 after 10 years of operation. As a result of the corresponding increase in radiation and pileup, the electromagnetic calorimetry in the CMS endcaps will sustain maximum integrated doses of 1.5 MGy and neutron fluences above 1e16 neq/cm2, necessitating their replacement for HL-LHC operation. The CMS collaboration has decided to replace the existing endcap electromagnetic and hadronic calorimeters by a High Granularity Calorimeter (HGCAL) that will provide unprecedented information on electromagnetic and hadronic showers in the very high pileup of the HL-LHC. In order to employ Si detectors in HGCAL and to address the challenges brought by the intense radiation environment, an extensive R&D program has been initiated, comprising production of prototype sensors of various types, sizes and thicknesses, their qualification before and after irradiation to the expected levels, and accompanying simulation studies. The ongoing investigation presented here includes measurements of current-voltage and capacitance-voltage characteristics, along with predicted charge collection efficiences of the sensors irradiated to levels expected for the HGCAL at HL-LHC. The status of the study and the first results of the performance of neutron irradiated Si detectors, as well as their comparison with numerical simulations, are presented.

Explore related subjects

Keep this discovery

BibTeXRIS

Timo Peltola. 2017-11-14. Experimental and simulation study of irradiated silicon pad detectors for the CMS High Granularity Calorimeter. https://doi.org/10.1109/nssmic.2017.8532957

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det