Sensitivity analysis on imaging the calcaneus using microwaves

Abstract

The bone quality is asociated with changes in its dielectric properties (permittivity and conductivity). The feasibility of detecting changes in these properties is evaluated using a tomographic array of 16 monopole antennas with z-polarized microwaves at 1.3GHz. The direct problem was evaluated computationally with the Finite-Difference-Time-Domain (FDTD) method. Local and global sensitivity analysis were considered for identifiyng the parameters that most affect the detection. We observed that the direct problem is highly sensitive to the conductivity of the tissues that surround the calcaneus and the one of the calcaneus itself. Global and local sensitivity methods have shown evidences for feasible detection of variation in dielectric properties of bone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jesús E. Fajardo, Fernando Vericat, Guadalupe Irastorza, C. Manuel Carlevaro, Ramiro M. Irastorza. 2017-09-14. Sensitivity analysis on imaging the calcaneus using microwaves. https://doi.org/10.1088/2057-1976%2Fab3330

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Conceptualization of electronic dose to water and water-equivalent gas for ionometric dosimetry in external beam radiotherapy

Electronic dose to water, which is the radiant energy imparted to a unit mass of water by electronic collisions, is conceptualized to exclude corrections and uncertainties associated with energy transfer to atomic nuclei and to enhance medical relevance in radiotherapy dosimetry. Based on the international code of practice, the procedures to determine electronic doses were formulated for high-energy photon, electron, proton, and ion beams. Nitrogen-based water-equivalent gas (WEG) mixtures were designed for use in gas-sealed ionization chambers for proton and ion beams. A thought experiment of reference dosimetry for electronic dose demonstrated its compatibility with absorbed dose for photon and electron beams. For proton and ion beams, the transition from absorbed dose to electronic dose will change the measured dose values by -1.4% and -2.2%, and decrease the uncertainty from 1.6% to 1.5% and from2.6% to 2.1%, respectively. With WEG ionization chambers, the uncertainty will further decrease to 1.2% for proton beams and 1.5% for ion beams. The formulated framework will be applicable to radiotherapy dosimetry with traceable dosimeter calibration under the international measurement system for radiation metrology.

physics.med-ph

A novel methodology to estimate pileup effects and induced error in microdosimetric spectra

Microdosimetry provides a superior characterization of the radiation field compared to conventional LET-based methodology, and for this reason it has become increasingly attractive for quality assurance in particle therapy. However, the typical particle rates used in the treatments lead to pileup, which distorts the experimental spectra, and thus compromises the accuracy of microdosimetric measurements, limiting their use in clinical settings. In this work, we investigated the pileup in a spherical Tissue Equivalent Proportional Counter (TEPC), and developed an algorithm to evaluate the contribution of this effect to the measured spectra. We exposed the TEPC to 11 and 70 MeV proton beams, and collected the microdosimetric spectra at rates in the $10^3$-$10^6$ pps range. Using a combination of GEANT4 Monte Carlo simulations and experimental data, we develop an algorithm capable of estimating the pileup probability affecting experimental measurements. The data suggest that the pileup probability has a linear increase with rate until it reaches a value of $15 \pm 3 \, \%$ at $28.2 \times 10^3$ pps, at which point it begins to saturate. Additionally, the outcomes from the comparison of the two proton energies suggest that the methodology used to estimate pileup can be used to predict the effects in clinical proton beams with similar energies. This same methodology can be applied to any type of microdosimetric measurement making it a reliable tool for addressing pileup issues and facilitating the application of microdosimetry in clinical settings.

physics.med-ph