$^{3}$He-$^{129}$Xe Comagnetometery using $^{87}$Rb Detection and Decoupling
Abstract
We describe a $^{3}$He-$^{129}$Xe comagnetometer using $^{87}$Rb atoms for noble-gas spin polarization and detection. We use a train of $^{87}$Rb $π$ pulses and $σ^+/σ^-$ optical pumping to realize a finite-field Rb magnetometer with suppression of spin-exchange relaxation. We suppress frequency shifts from polarized Rb by measuring the $^{3}$He and $^{129}$Xe spin precession frequencies in the dark, while applying $π$ pulses along two directions to depolarize Rb atoms. The plane of the $π$ pulses is rotated to suppress the Bloch-Siegert shifts for the nuclear spins. We measure the ratio of $^{3}$He to $^{129}$Xe spin precession frequencies with sufficient absolute accuracy to resolve the Earth's rotation without changing the orientation of the comagnetometer. A frequency resolution of 7 nHz is achieved after integration for 8 hours without evidence of significant drift.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
M. E. Limes, D. Sheng, M. V. Romalis. 2017-11-14. $^{3}$He-$^{129}$Xe Comagnetometery using $^{87}$Rb Detection and Decoupling. https://doi.org/10.1103/physrevlett.120.033401