arXiv ScienceSearch

arXiv · 1702.06071

A Neutron Spin-Echo Concept for Elastic Scattering Spectroscopy (ESS) for Dynamics of Complex (Bio-) Systems

Abstract

Recently, a new neutron spectroscopy for the dynamics in complex (bio-) systems has been proposed [A. Benedetto, and G. J. Kearley, Sci. Rep. 6, 34266, (2016)]. This spectroscopy is ideal where only the overall relaxation time in a parameterless way is required, for example in complex systems, because only the elastic-scattering intensity as a function of the energy resolution is required. This has been termed "Elastic Scattering Spectroscopy" (ESS). It is based on the inflection points in the elastic-scattering intensity at the energy-resolution value corresponding to the overall system relaxation-time. A Constant wavelength (CW) option, more suitable for reactor sources, and the time-of-flight (TOF) option, more suitable for spallation sources, have already been proposed, and here we examine the concept of a third option based on neutron spin-echo (NSE), called ESS-NSE. In principle, this consists of simply measuring depolarisation at the relatively-intense elastic echo-condition, as a function of resolution, with the basic set-up being similar to standard spin-echo. In its basic set-up, ESS spin-echo can access 5 orders of magnitude in time from nanoseconds to tens of picoseconds, reaching slower relaxation processes than the CW and TOF options recently presented. However, spatial focussing is important for the small sample-sizes of biological systems, so we also explore how the fields may be shaped to enable a small neutron beam to be focussed on the sample.

Explore related subjects

Keep this discovery

BibTeXRIS

Antonio Benedetto, Gordon J. Kearley. 2017-02-20. A Neutron Spin-Echo Concept for Elastic Scattering Spectroscopy (ESS) for Dynamics of Complex (Bio-) Systems. https://arxiv.org/abs/1702.06071

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det