arXiv · 1701.04514
Performance of a prototype active veto system using liquid scintillator for a dark matter search experiment
Abstract
We report the performance of an active veto system using a liquid scintillator with NaI(Tl) crystals for use in a dark matter search experiment. When a NaI(Tl) crystal is immersed in the prototype detector, the detector tags 48% of the internal K-40 background in the 0-10 keV energy region. We also determined the tagging efficiency for events at 6-20 keV as 26.5 +/- 1.7% of the total events, which corresponds to 0.76 +/- 0.04 events/keV/kg/day. According to a simulation, approximately 60% of the background events from U, Th, and K radioisotopes in photomultiplier tubes are tagged at energies of 0-10 keV. Full shielding with a 40-cm-thick liquid scintillator can increase the tagging efficiency for both the internal K-40 and external background to approximately 80%.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J. S. Park, P. Adhikari, G. Adhikari, S. Y. Oh, N. Y. Kim, Y. D. Kim, C. Ha, K. S. Park, H. S. Lee, E. J. Jeon. 2017-01-17. Performance of a prototype active veto system using liquid scintillator for a dark matter search experiment. https://doi.org/10.1016/j.nima.2017.01.041
Cite the original work for its findings. Save a collection to share your selection of sources.