Negative Feedback, Linearity and Parameter Invariance in Linear Electronics

Abstract

Negative feedback is a powerful approach capable of improving several aspects of a system. In linear electronics, it has been critical for allowing invariance to device properties. Negative feedback is also known to enhance linearity in amplification, which is one of the most important foundations of linear electronics. At the same time, thousands of transistors types have been made available, suggesting that these devices, in addition to their known variability of parameters, have distinguishing properties. The current work reports a systematic approach to quantifying the potential of negative feedback, with respect to bipolar transistors, as a means to providing device invariance and linearity. Several methods, including concepts from multivariate statistics and complex systems, are applied at the theoretical as well as experimental levels, and a number of interesting results are obtained and discussed. For instance, it has been verified that the transistors types indeed have well-defined characteristics which clearly segregate them into groups. The addition of feedback at moderate and intense levels promoted uniformization of the properties of these transistors when used in a class A common emitter configuration. However, such effect occurred with different efficiency regarding the considered device features, and even intense feedback was unable to completely eliminate device dependence. This indicates that it would be interesting to consider the device properties in linear design even when negative feedback is applied. We also verified that the linearization induced in the considered experiments is relatively modest, with effects that depend on type of transfer function of the original devices.

Explore related subjects

Keep this discovery

BibTeXRIS

Luciano da F. Costa, Filipi N. Silva, Cesar H. Comin. 2016-11-19. Negative Feedback, Linearity and Parameter Invariance in Linear Electronics. https://arxiv.org/abs/1611.06356

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det