arXiv · 1611.00151
Design and Test of Wire-Scanners for SwissFEL
Abstract
The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.8 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam transverse profile without suffering from possible micro-bunching of the electron beam. The main aspects of the design, laboratory characterization and beam-test of the SwissFEL wire-scanner prototype will be discussed.
Explore related subjects
Keep this discovery
G. L. Orlandi, M. Baldinger, H. Brands, P. Heimgartner, R. Ischebeck, A. Kammerer, F. Löhl, R. Lüscher, P. Mohanmurthy, C. Ozkan, V. Schlott, L. Schulz, B. Rippstein, C. Seiler, S. Trovati, P. Valitutti, D. Zimoch. 2016-11-01. Design and Test of Wire-Scanners for SwissFEL. https://arxiv.org/abs/1611.00151
Cite the original work for its findings. Save a collection to share your selection of sources.