arXiv ScienceSearch

arXiv · 1609.00002

A torsion pendulum ground test of the LISA Pathfinder Free-fall mode

Abstract

LISA Pathfinder is the technological demonstrator space mission for the future gravitational waves observatory in space eLISA, with the aim of measure the differential acceleration between free-falling test masses orbiting in the same apparatus at a level of 30 fm/s-2Hz-1/2 at 1 mHz. Because the satellite can't follow the two masses at the same time, the second mass must be forced to follow either the other one or the spacecraft. The actuation force applied to compensate this effect introduces a dominant source of force noise in the mission noise budget at frequency near and below the mHz. The free-fall mode actuation control scheme has been designed to suppress this noise source and avoid actuation instabilities: actuation is limited to brief periodic impulses, with test masses in free fall in between two kicks. This actuation-free motion is then analyzed for the remaining sources of acceleration ultra noise. A free-fall mode parallel testing has been successfully implemented on torsion pendulum facility at the University of Trento and the results of the measurement campaign are ready to be shown and discussed. The implementation of the data analysis algorithms to estimate the spectrum of the acceleration of the controlled test mass, and the estimation of system parameters such as the force gradients, stiffness terms, are also part of this work. The free-fall mode has been tested at the level of 2 fNm/Hz-1/2, at the frequencies of 1 mHz, corresponding to an acceleration of about 100 fm /s-2 Hz-1/2. The ground tests have nevertheless allowed to develop and test quantitatively this innovative method of noise reduction due to actuation noise, contributing to its development for the LISA Pathfinder mission.

Explore related subjects

Keep this discovery

BibTeXRIS

Giuliana Russano. 2016-08-30. A torsion pendulum ground test of the LISA Pathfinder Free-fall mode. https://arxiv.org/abs/1609.00002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det