Efficient Image Reconstruction and Practical Decomposition for Dual-energy Computed Tomography

Abstract

Dual-energy computed tomography (DECT) has shown great potential and promising applications in advanced imaging fields for its capabilities of material decomposition. However, image reconstructions and decompositions under sparse views dataset suffers severely from multi factors, such as insufficiencies of data, appearances of noise, and inconsistencies of observations. Under sparse views, conventional filtered back-projection type reconstruction methods fails to provide CT images with satisfying quality. Moreover, direct image decomposition is unstable and meet with noise boost even with full views dataset. This paper proposes an iterative image reconstruction algorithm and a practical image domain decomposition method for DECT. On one hand, the reconstruction algorithm is formulated as an optimization problem, which containing total variation regularization term and data fidelity term. The alternating direction method is utilized to design the corresponding algorithm which shows faster convergence speed compared with the existing ones. On the other hand, the image domain decomposition applies the penalized least square (PLS) estimation on decomposing the material mappings. The PLS includes linear combination term and the regularization term which enforces the smoothness on estimation images. The authors implement and evaluate the proposed joint method on real DECT projections and compare the method with typical and state-of-the-art reconstruction and decomposition methods. The experiments on dataset of an anthropomorphic head phantom show that our methods have advantages on noise suppression and edge reservation, without blurring the fine structures in the sinus area in the phantom. Compared to the existing approaches, our method achieves a superior performance on DECT imaging with respect to reconstruction accuracy and decomposition quality.

Explore related subjects

Keep this discovery

BibTeXRIS

Lei Li, Ailong Cai, Linyuan Wang, Bin Yan, Hanming Zhang, Zhizhong Zheng, Wenkun Zhang, Wanli Lu, Guoen Hu. 2016-07-06. Efficient Image Reconstruction and Practical Decomposition for Dual-energy Computed Tomography. https://arxiv.org/abs/1607.01650

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph