We show that with spatially incoherent illumination, the point spread function width of an imaging interferometer like that used in full-field optical coherence tomography (FFOCT) is almost insensitive to aberrations that mostly induce a reduction of the signal level without broadening. This is demonstrated by comparison with traditional scanning OCT and wide-field OCT with spatially coherent illuminations. Theoretical analysis, numerical calculation as well as experimental results are provided to show this specific merit of incoherent illumination in full-field OCT. To the best of our knowledge, this is the first time that such result has been demonstrated.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Peng Xiao, Mathias Fink, A. Claude Boccara. 2016-06-22. Spatially incoherent illumination interferometry: a PSF almost insensitive to aberrations. https://doi.org/10.1364/ol.41.003920