Abstract
The design, construction and test of a charged particle detector made of scintillation counters read by Silicon Photomultipliers (SiPM) is described. The detector, which operates in vacuum and is used as a veto counter in the NA62 experiment at CERN, has a single channel time resolution of 1.14 ns, a spatial resolution of ~2.5 mm and an efficiency very close to 1 for penetrating charged particles.
Explore related subjects
Keep this discovery
F. Ambrosino, T. Capussela, D. Di Filippo, P. Massarotti, M. Mirra, M. Napolitano, V. Palladino, G. Saracino, L. Roscilli, A. Vanzanella, G. Corradi, D. Tagnani, U. Paglia. 2015-12-01. CHANTI: a Fast and Efficient Charged Particle Veto Detector for the NA62 Experiment at CERN. https://doi.org/10.1088/1748-0221/11/03/p03029