Study of gain variation as a function of physical parameters of GEM foil
Abstract
The ALICE experiment at LHC has planned to upgrade the TPC by replacing the MWPC with GEM based detecting elements to restrict the IBF to a tolerable value. However the variation of the gain as a function of physical parameters of industrially produced large size GEM foils is needed to be studied as a part of the QA procedure for the detector. The size of the electron avalanche and consequently the gain for GEM based detectors depend on the electric field distribution inside the holes. Geometry of a hole plays an important role in defining the electric field inside it. In this work we have studied the variation of the gain as a function of the hole diameters using Garfield++ simulation package.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Supriya Das. 2015-06-22. Study of gain variation as a function of physical parameters of GEM foil. https://doi.org/10.1016/j.nima.2015.11.078