arXiv · 1505.07592
Effect of the interface resistance in non-local Hanle measurements
Abstract
We use lateral spin valves with varying interface resistance to measure non-local Hanle effect in order to extract the spin-diffusion length of the non-magnetic channel. A general expression that describes spin injection and transport, taking into account the influence of the interface resistance, is used to fit our results. Whereas the fitted spin-diffusion length value is in agreement with the one obtained from standard non-local measurements in the case of a finite interface resistance, in the case of transparent contacts a clear disagreement is observed. The use of a corrected expression, recently proposed to account for the anisotropy of the spin absorption at the ferromagnetic electrodes, still yields a deviation of the fitted spin-diffusion length which increases for shorter channel distances. This deviation shows how sensitive the non-local Hanle fittings are, evidencing the complexity of obtaining spin transport information from such type of measurements.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Estitxu Villamor, Luis E. Hueso, Fèlix Casanova. 2015-05-28. Effect of the interface resistance in non-local Hanle measurements. https://doi.org/10.1063/1.4922247
Cite the original work for its findings. Save a collection to share your selection of sources.